A compilation of fluence-to-absorbed dose conversion coefficients for the dose to the lens of the eye is presented. The compilation consists of both previously data and newly calculated values: photon data ( 5 keV to 50 MeV for both kerma approximation and full electron transport), electron data (10 keV to 50 MeV), and positron data (1 keV to 50 MeV) - neutron data will be published separately. Values are given for angles of incidence from 0° up to 90° in steps of 15° and for rotational irradiation. The data presented can be downloaded from this article's website and they are ready for use by Report Committee (RC) 26. This committee has been set up by the International Commission on Radiation Units and Measurements (ICRU) and is working on a "proposal for a redefinition of the operational quantities for external radiation exposure".
Kostenfreier Zugang
Open Access Hybrid
Rechteinformation
CC BY 4.0 ; Creative Commons Attribution 4.0 License
Zitierung
Behrens, R. (2017). Compilation of conversion coefficients for the dose to the lens of the eye. Radiation Protection Dosimetry, 174(3), 348–370. https://doi.org/10.1093/rpd/ncw194