Titel Vergleich der dynamischen Konturtonometrie vs. Goldmann-Applanationstonometrie nach dem internationalen Standard für Augentonometer (ISO 8612) in einem Glaukomkollektiv
Übersetzungstitel Comparison of dynamic contour tonometry versus Goldmann applanation tonometry according to the International Ocular Tonometer Standards ISO 8612 in glaucoma patients
Autor(in); Institution
Pahlitzsch, M.; Augenklinik, Charité Berlin, Berlin, GERMANY
Gonnermann, J.; Augenklinik, Charité Berlin, Berlin, GERMANY
Maier, A.K.; Augenklinik, Charité Berlin, Berlin, GERMANY
Schwenteck, Thomas; 8.1, Medizinische Messtechnik, PTB-Berlin
Torun, N.; Augenklinik, Charité Berlin, Berlin, GERMANY
Bertelmann, E.; Augenklinik, Charité Berlin, Berlin, GERMANY
Klamann, M. K.; Augenklinik, Charité Berlin, Berlin, GERMANY
Quelle/Jahr Klinische Monatsblätter für Augenheilkunde: 231 (2014), 11, 1107 - 1113
ISSN 0023-2165 (PRINT) ; 1439-3999 (ONLINE)
DOI
Verlag Stuttgart: Thieme
Zusammenfassung INTRODUCTION: The aim of this study was to compare the dynamic contour tonometry PASCAL® (DCT) versus the Goldmann applanation tonometry (GAT) in a glaucoma population and to analyse the correlation with the central corneal thickness (CCT). PATIENTS/METHODS: 191 eyes of 107 Caucasian glaucoma patients (62 female, 45 male) were included: 3 repeated GAT and dynamic contour tonometry (DCT) measurements (quality factor 1-2) were analysed. CCT was measured by ultrasound pachymetry. Criteria of ISO 8612 were fulfilled: 3 groups of IOP measurements were formed: group 1: 7-16 mmHg, group 2: 16-23 mmHg and group 3: ) 23 mmHg, each including at least 40 eyes. Only 5.0 % outliers per area of intraocular pressure were permitted in a tolerance of ± 5.0 mmHg. RESULTS: Data of 191 eyes (mean CCT 553 µm) were analysed. GAT (19.68 mmHg ± 7.56 mmHg) showed good correlation to DCT (20.54 ± 8.21 mmHg) (r = 0.770, p ( 0.001). Mean difference DCT-GAT was 0.86 ± 2.45 mmHg. In regard to the criteria of ISO 8612, the number of outliers were: group 1: (n = 68) 29.4 %, group 2: (n = 62) 41.9 %, and group 3: (n = 61) 31.2 %. No correlation was shown between CCT vs. GAT (r = 0.184, p = 0.057) and CCT vs. DCT (r = 0.177, p = 0.09), respectively. DISCUSSION: In conclusion, despite good correlation to GAT measurements DCT does not fulfil the ISO 8612 reference criteria in glaucoma patients. DCT and GAT did not show correlation to CCT.

Zitierung

Pahlitzsch, M., Gonnermann, J., Maier, A., Schwenteck, T., Torun, N., Bertelmann, E., & Klamann, M. K. (2014). Vergleich der dynamischen Konturtonometrie vs. Goldmann-Applanationstonometrie nach dem internationalen Standard für Augentonometer (ISO 8612) in einem Glaukomkollektiv. Klinische Monatsblätter für Augenheilkunde, 231(11), 1107–1113. https://doi.org/10.1055/s-0034-1383012

Exportieren