Zugriffsnummer 33710
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine
Übersetzungstitel Dosisleistungskonstanten für die Messgröße Hp(3) für häufig eingesetzte Nuklide in der Nuklearmedizin
Autor(in); Institution
Szermerski, Bastian; Medizinische Hochschule Hannover (MHH), Hannover, GERMANY
Bruchmann, Iris; Medizinische Hochschule Hannover (MHH), Hannover, GERMANY
Behrens, Rolf; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Geworski, Lilli; Medizinische Hochschule Hannover (MHH), Hannover, GERMANY
Quelle/Jahr Zeitschrift für Medizinische Physik: 26 (2016), 4, 304 - 310
ISSN 0939-3889
DOI
Verlag Amsterdam: Elsevier
Zusammenfassung According to recent studies, the human eye lens is more sensitive to ionising radiation than previously assumed. Therefore, the dose limit for personnel occupationally exposed to ionising radiation will be lowered from currently 150 mSv to 20 mSv per year. Currently, no data base for a reliable estimation of the dose to the lens of the eye is available for nuclear medicine. Furthermore, the dose is usually not monitored. The aim of this work was to determine dose rate constants for the quantity Hp(3), which is supposed to estimate the dose to the lens of the eye. For this, Hp(3)-dosemeters were fixed to an Alderson Phantom at different positions. The dosemeters were exposed to radiation from nuclides typically used in nuclear medicine in their geometries analog to their application in nuclear medicine, e.g. syringe or vial. The results show that the handling of high-energy beta (i.e. electron or positron) emitters may lead to a relevant dose to the lens of the eye. For low-energy beta emitters and gamma emitters, an exceeding of the lowered dose limit seems to be unlikely.

Zitierung

Szermerski, B., Bruchmann, I., Behrens, R., & Geworski, L. (2016). Dose rate constants for the quantity Hp(3) for frequently used radionuclides in nuclear medicine. Zeitschrift für Medizinische Physik, 26(4), 304–310. https://doi.org/10.1016/j.zemedi.2015.11.003

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag