| Zugriffsnummer | 33674 |
| Dokumenttyp | Zeitschriftenartikel |
| Peer Review | unbekannt |
| Sprache | Englisch |
| Titel | Results of the EURAMET.RI(I)-S6.I-129 supplementary comparison |
| Autor(in); Institution |
Garcia-Torano, Eduardo; Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, SPAIN
Altzitzoglou, Timotheos; European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Geel, BELGIUM
Auerbach, Pavel; Czech Metrological Institute (CMI), Prague, CZECH REPUBLIC
Bé, Marie-Martine; Laboratoire National Henri Becquerel, LNE-LNHB, Gif sur Yvette Cedex, FRANCE
Lourenco, Valérie; Laboratoire National Henri Becquerel, LNE-LNHB, Gif sur Yvette Cedex, FRANCE
Bobin, Christophe; Laboratoire National Henri Becquerel, LNE-LNHB, Gif sur Yvette Cedex, FRANCE
Cassette, Philippe; Laboratoire National Henri Becquerel, LNE-LNHB, Gif sur Yvette Cedex, FRANCE
Dersch, Rainer; 6.1, Radioaktivität, PTB-Braunschweig
Kossert, Karsten; 6.1, Radioaktivität, PTB-Braunschweig
Nähle, Ole Jens; 6.1, Radioaktivität, PTB-Braunschweig
Peyrés, Virginia; Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, SPAIN
Pommé, Stefaan; European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Geel, BELGIUM
Rozkov, Andrej; European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Geel, BELGIUM
Sanchez-Cabezudo, Ana Isabel; Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, SPAIN
Sochorov.aacute., Jana; Czech Metrological Institute (CMI), Prague, CZECH REPUBLIC
|
| Quelle/Jahr | Metrologia: 52 (2015), Tech. Suppl., 16 S. |
| Artikelnummer | 06017 |
| Availability | [online only] |
| ISSN | 0026-1394 |
| DOI | |
| Verlag | Bristol [u.a.]: IOP [u.a.] |
| Zusammenfassung | An international comparison of the long-lived gamma-ray emitter 129I has been recently completed. A total of 5 laboratories measured a solution prepared by Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT). Aliquots of the master solution were standardized in terms of activity per mass unit by participant laboratories using 4 different techniques. The results of the comparison can be used as the basis for establishing the equivalence among the laboratories. |
Zitierung
Garcia-Torano, E., Altzitzoglou, T., Auerbach, P., Bé, M.-M., Lourenco, V., Bobin, C., Cassette, P., Dersch, R., Kossert, K., Nähle, O. J., Peyrés, V., Pommé, S., Rozkov, A., Sanchez-Cabezudo, A. I., & Sochorov.aacute., J. (2015). Results of the EURAMET.RI(I)-S6.I-129 supplementary comparison. Metrologia, 52(Tech. Suppl.), 16 S. https://doi.org/10.1088/0026-1394/52/1a/06017