Zugriffsnummer 33459
Dokumenttyp Konferenzartikel in Zeitschrift
Sprache Englisch
Titel Intercomparison of radiation temperature measurements with filtered detectors over the temperature range 1380 K to 3100 K
Autor(in); Institution
Harrison, N. J.; Centre for Optical and Environmental Metrology, National Physical Laboratory (NPL), Teddington, Middlesex, UK
Fox, N. P.; Centre for Optical and Environmental Metrology, National Physical Laboratory (NPL), Teddington, Middlesex, UK
Sperfeld, Peter; 4.11, Radiometrische Einheiten, PTB-Braunschweig
Metzdorf, Jürgen; 4.1, Licht und Strahlung, PTB-Braunschweig
Khlevnoy, B. B.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Stolyarevskaya, R. I.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Khromchenko, V. B.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Mekhontsev, S. N.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Shapoval, V. I.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Zelener, M. F.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Sapritsky, V. I.; All-Russian Research Institute for Optophysical Measurements, (VNIIOFI), Moscow, RUSSIA
Quelle/Jahr Metrologia: 35 (1998), 4, 283 - 288
ISSN 0026-1394 (PRINT) ; 1681-7575 (ONLINE)
DOI
Verlag Bristol [u.a.]: Institute of Physics Publishing (IOP) ; Bureau International des Poids et Mesures
Konferenzangaben 6th International Conference on Radiometry, NEWRAD '97, Tucson, Ariz., 27-29, October, 1997, USA
Klassifikationscode PACS: 42.72.-g ; PACS: 44.40.+a ; PACS: 02.40.-k ; PACS: 07.60.Dq
Zusammenfassung A series of black-body radiation-temperature measurements has been made over the temperature range 1380 K to 3100 K using two different designs of pyrolytic-graphite black bodies with calculated emissivities of 0.999. All measurements were performed at the All-Russian Research Institute for Optophysical Measurements (VNIIOFI) during June 1997. A filter photometer from the VNIIOFI, broadband glass-filter detectors from the Physikalisch-Technische Bundesanstalt (PTB) and narrowband interference-filter-based radiometers from the National Physical Laboratory (NPL) were used to perform the temperature measurements in either radiance or irradiance mode using both black bodies. Across the entire temperature range, the NPL and PTB instruments showed consistent results with both black bodies and differing geometrical arrangements. Results from the VNIIOFI photometer were also broadly consistent for a wide temperature range.

Zitierung

Harrison, N. J., Fox, N. P., Sperfeld, P., Metzdorf, J., Khlevnoy, B. B., Stolyarevskaya, R. I., Khromchenko, V. B., Mekhontsev, S. N., Shapoval, V. I., Zelener, M. F., & Sapritsky, V. I. (1998). Intercomparison of radiation temperature measurements with filtered detectors over the temperature range 1380 K to 3100 K. Metrologia, 35(4), 283–288. https://doi.org/10.1088/0026-1394/35/4/12

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag