Zugriffsnummer 33334
Dokumenttyp Zeitschriftenartikel
Peer Review unbekannt
Sprache Englisch
Titel A new two-stage separation procedure for the IDMS based quantification of low Pd and Pt amounts in automotive exhaust emissions.
Autor(in); Institution
Vogl, Jochen; Federal Institute for Materials Research and Testing (BAM), Berlin, GERMANY
Meyer, Christian; Federal Institute for Materials Research and Testing (BAM), Berlin, GERMANY
Koenig, Maren; Federal Institute for Materials Research and Testing (BAM), Berlin, GERMANY
Becker, Dorit; Federal Institute for Materials Research and Testing (BAM), Berlin, GERMANY
Noordmann, Janine; 3.1, Metrologie in der Chemie, PTB-Braunschweig
Rienitz, Olaf; 3.1, Metrologie in der Chemie, PTB-Braunschweig
Mamakos, Athanasios; Joint Research Centre (JRC), Ispra, ITALY
Riccobonoc, Francesco; Joint Research Centre (JRC), Ispra, ITALY
Quelle/Jahr Journal of analytical atomic spectrometry: 30 (2015), 2, 479 - 486
ISSN 0267-9477 (PRINT) ; 1364-5544 (ONLINE)
DOI
Verlag London: Royal Society of Chemistry (RSC)
Zusammenfassung A two-step separation procedure for the quantification of Pd and Pt in automotive exhaust emissions using isotope dilution mass spectrometry was established using a combination of cation and anion exchange chemistry. AG 50W-X12 was used as cation exchange resin and DGA as weakly basic anion exchange resin. This procedure enabled the effective separation of Pd and Pt from the matrix and from interfering elements. Additionally Pd and Pt were collected in separate chromatographic fractions, which increased the precision of the isotope ratio determination by separate measurements using single collector sector field ICPMS. The analytical procedure was validated by analysing the synthetically prepared samples and the certified reference materials BCR-723 (road dust) and IAEA-450 (algae). For the SI-traceable results complete uncertainty budgets were calculated yielding relatively expanded uncertainties (k = 2) of ≈1% for analyte masses in the ng range. Procedure blanks of 55 pg Pd and 3 pg Pt were obtained. The detection limits were calculated as 12 pg for Pd and 7 pg for Pt. Additionally, Pd and Pt blank levels of different filter materials are presented as well as the first results for automotive exhaust particles collected on cellulose filters.

Zitierung

Vogl, J., Meyer, C., Koenig, M., Becker, D., Noordmann, J., Rienitz, O., Mamakos, A., & Riccobonoc, F. (2015). A new two-stage separation procedure for the IDMS based quantification of low Pd and Pt amounts in automotive exhaust emissions. Journal of analytical atomic spectrometry, 30(2), 479–486. https://doi.org/10.1039/c4ja00251b