| Zugriffsnummer | 33170 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | Reestablishment of the primary AC voltage standard at KRISS |
| Autor(in); Institution |
Kwon, Sung-Won; Korea Research Institute of Standards and Science, Taejon, SOUTH KOREA
Park, S. I.; Korea Research Institute of Standards and Science, Taejon, SOUTH KOREA
Kim, Kyu-Tae; Korea Research Institute of Standards and Science, Taejon, SOUTH KOREA
Cho, Y. M.; Korea Research Institute of Standards and Science, Taejon, SOUTH KOREA
Klonz, Manfred; 2.32, Wechsel-Gleich-Transfer, PTB-Braunschweig
|
| Quelle/Jahr | 1998 Conference on Precision Electromagnetic Measurements: digest:(1998), 510 - 511 |
| Herausgeber(in) |
Nelson, Thomas L.
|
| ISBN | 0-7803-5018-9 |
| DOI | |
| Verlag | Piscataway, NJ: IEEE Service Center |
| Konferenzangaben | Conference on Precision Electromagnetic Measurements, CPEM, Washington, DC, 06-10, July, 1998, USA |
| Freie Schlagworte | calibration ; convertors ; measurement uncertainty ; transfer standards ; voltage measurement |
| Zusammenfassung | Thin-film multijunction thermal converters have been introduced as primary AC-DC voltage transfer standards at KRISS. The evaluation of the standards from an extensive series of comparisons and analysis of the error sources by using a new automatic AC-DC difference measurement system and the fast-reversed DC source is described. The agreement between the two systems is better than 1 ppm up to 4 V and 10 kHz. |
Zitierung
Kwon, S.-W., Park, S. I., Kim, K.-T., Cho, Y. M., & Klonz, M. (1998). Reestablishment of the primary AC voltage standard at KRISS. Conference on Precision Electromagnetic Measurements, CPEM, Washington, DC, 06-10, July, 1998, USA. https://doi.org/10.1109/cpem.1998.700030