| Zugriffsnummer | 32698 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | Electromagnetic susceptibility of control area network modules |
| Autor(in); Institution |
Novak, J.; Czech Tech. University, Dept. of Measurement, Prague 6, CZECH REPUBLIC
Stepka, Z.; Czech Tech. University, Dept. of Measurement, Prague 6, CZECH REPUBLIC
Kocourek, P.; Czech Tech. University, Dept. of Measurement, Prague 6, CZECH REPUBLIC
Schumny, Harald; 10.4, Rechnerintegrierte Meßdatenverarbeitung, PTB-Berlin
Zisky, Norbert; 10.42, Messdatenübertragungstechnik, PTB-Berlin
Neumann, Jörg; 10.42, Messdatenübertragungstechnik, PTB-Berlin
|
| Quelle/Jahr | Proceedings: 9th International Symposium on Electrical Instruments in Industry : September 8 - 9, 1997, Glasgow, Scotland:(1997), 81 - 84 |
| ISBN | 0-9531409-2-X |
| Verlag | Glasgow: Industrial Control Centre, University of Strathclyde |
| Konferenzangaben | 9th International Symposium on Electrical Instruments in Industry, Glasgow, September 8 - 9, 1997, Scotland |
| Zusammenfassung | This contribution intends to describe the electromagnetic susceptibility testing method of CAN modules based on the IEC 1000-4-4 standard. A new feature of this method is the using of module with very high susceptibility and easy connection of CAN analyzer. Performed tests brought several interesting points in behaviour of the bus under distortion. |