Zugriffsnummer 31032
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Establishment of a primary reference solar cell calibration technique in Korea: methods, results and comparison with WPVS qualified laboratories
Autor(in); Institution
SeungKyu, Ahn; Korea Institute of Energy Research, Solar Energy Department, Yuseong-Gu, Daejeon, KOREA
SeJin, Ahn; Korea Institute of Energy Research, Solar Energy Department, Yuseong-Gu, Daejeon, KOREA
Jae Ho, Yun; Korea Institute of Energy Research, Solar Energy Department, Yuseong-Gu, Daejeon, KOREA
Dong-Hoon, Lee; Korea Research Institute of Standards and Science, Center for Photometry and Radiometry, Yuseong-Gu, Daejeon, KOREA
Winter, Stefan; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Sanekazu, Igari; National Institute of Advanced Industrial Science and Technology, Research Center for Photovoltaics, Tsukuba, Ibaraki, JAPAN
KyungHoon, Yoon; Korea Institute of Energy Research, Solar Energy Department, Yuseong-Gu, Daejeon, KOREA
Quelle/Jahr Metrologia: 51 (2014), 3, 139 - 147
ISSN 0026-1394
DOI
Verlag Bristol: IOP
Freie Schlagworte primary reference solar cell ; indoor calibration ; ACR ; multiple reflection effect
Zusammenfassung A primary reference solar cell calibration technique recently established at the Korea Institute of Energy Research in Korea is introduced. This calibration technique is an indoor method that uses a highly collimated continuous-type solar simulator and absolute cavity radiometer traceable to the World Radiometric Reference. The results obtained using this calibration technique are shown with a precise uncertainty analysis, and the system configuration and calibration procedures are introduced. The calibration technique avoids overestimating the short-circuit current of a reference solar cell due to multiple reflections of incident simulator light using a novel method. In addition, the uncertainty analysis indicates that the calibration technique has an expanded uncertainty of approximately 0.7% with a coverage factor of k = 2 for a c-Si reference cell calibration. In addition, the developed primary reference solar cell calibration technique was compared with other techniques established in the World Photovoltaic Scale (WPVS) qualified calibration laboratories to verify its validity and reliability.

Zitierung

SeungKyu, A., SeJin, A., Jae Ho, Y., Dong-Hoon, L., Winter, S., Sanekazu, I., & KyungHoon, Y. (2014). Establishment of a primary reference solar cell calibration technique in Korea: methods, results and comparison with WPVS qualified laboratories. Metrologia, 51(3), 139–147. https://doi.org/10.1088/0026-1394/51/3/139