| Zugriffsnummer | 30356 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | Intercomparison between DTI - PTB - SP: intercomparison of the flow meter and thermal power calibration facilities for the flow of water at a temperature of 40°C between the Danish Technological Institute (DTI), Physikalisch-Technische Bundesanstalt (PTB) and Swedish National Testing Institute (SP) |
| Autor(in); Institution |
Thrane, Michael; Danish Technological Institut, Aarhus, DENMARK
Frederiksen, John; Danish Technological Institut, Aarhus, DENMARK
Stuck, Dieter; 7.33, Messung thermischer Energie, PTB-Berlin
Fenske, Helmut; Swedish National Testing and Research Institute, Borås, SWEDEN
|
| Quelle/Jahr | FLOMEKO 98, the 9th International Conference on Flow Measurement: Proceedings:(2000), 101 - 104 |
| Herausgeber(in) |
Delsing, Jerker
|
| ISBN | 91-630-6991-1 |
| Verlag | Kista: ITF |
| Konferenzangaben | 9th International Conference on Flow Measurement, FLOMEKO 1998, Lund, 15-17, June, 1998, Sweden |
| Zusammenfassung | This paper presents the results of two intercalibrations carried out between three national laboratories during 1995 - 1997. The intercalibrations investigate the laboratories for flow calibration facilities for the flow of water for flow rates between 125 1/h - 2000 1/h, at a water temperature of 40°C. |
Zitierung
Thrane, M., Frederiksen, J., Stuck, D., & Fenske, H. (2000). Intercomparison between DTI - PTB - SP: intercomparison of the flow meter and thermal power calibration facilities for the flow of water at a temperature of 40°C between the Danish Technological Institute (DTI), Physikalisch-Technische Bundesanstalt (PTB) and Swedish National Testing Institute (SP). 9th International Conference on Flow Measurement, FLOMEKO 1998, Lund, 15-17, June, 1998, Sweden.