Zugriffsnummer 29976
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Comparison of CD measurements of an EUV photomask by EUV scatterometry and CD-AFM
Autor(in); Institution
Scholze, Frank; 7.1, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Soltwisch, Victor; 7.1, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Dai, Gaoliang; 5.2, Dimensionelle Nanometrologie, PTB-Braunschweig
Henn, Mark-Alexander; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Gross, Hermann; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Quelle/Jahr Photomask Technology 2013:(2013), 88800O-1 - 88800O-12
Schriftenreihe Proceedings of SPIE: 8880
Availability [CD-ROM] ; file name: 8880_23.pdf
Herausgeber(in)
Faure, Thomas B.
Ackermann, Paul W.
ISSN 0277-786X
ISBN 978-0-8194-9545-7
DOI
Verlag Bellingham, Wash.: SPIE
Konferenzangaben SPIE Photomask Technology, Monterey, Calif., 10-12, September, 2013, USA
Freie Schlagworte mask metrology ; EUV lithography ; line edge roughness ; line width roughness
Zusammenfassung EUV scatterometry is a potential high-throughput measurement method for the characterization of EUV photomask structures. We present a comparison of angle resolved extreme ultraviolet (EUV) scatterometry and critical dimension atomic force microscope (CD-AFM) as a reference metrology for measurements of geometrical parameters like line width (CD), height and sidewall angle of EUV photomask structures. The structures investigated are dense and semidense bright and dark lines with different nominal CDs between 140 nm and 540 nm. The results show excellent linearity of the critical dimension measured with both methods within a range of only 1.8 nm and an offset of the absolute values below 3 nm. A maximum likelihood estimation (MLE) method is used to reconstruct the shape parameters and to estimate their uncertainties from the measured scattering efficiencies. The newly developed CD-AFM at PTB allows versatile measurements of parameters such as height, CD, sidewall angle, line edge/width roughness, corner rounding, and pitch. It applies flared tips to probe steep and even undercut sidewalls and employs a new vector approaching probing (VAP) strategy which enables very low tip wear and high measurement flexibility. Its traceability is ensured by a set of calibrated step-height and reference CD standards.

Zitierung

Scholze, F., Soltwisch, V., Dai, G., Henn, M.-A., & Gross, H. (2013). Comparison of CD measurements of an EUV photomask by EUV scatterometry and CD-AFM. SPIE Photomask Technology, Monterey, Calif., 10-12, September, 2013, USA. https://doi.org/10.1117/12.2025827

Exportieren

PTB-Publica MenĂ¼

Sprache wechseln: uk flag