Titel Comparison of codes assessing radiation exposure of aircraft crew due to galactic cosmic radiation
Autor(in); Institution
Bottollier-Depois, J. F.; Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, FRANCE
Beck, P.; Austrian Institute of Technology (AIT), Vienna, AUSTRIA
Latocha, M.; Austrian Institute of Technology (AIT), Vienna, AUSTRIA
Mares, V.; Helmholtz-Zentrum München (HMGU), Institute of Radiation Protection, Neuherberg, GERMANY
Matthiä, D.; Deutsches Zentrum für Luft- und Raumfahrt (DLR), Institute of Aerospace Medicine, Köln, GERMANY
Rühm, W.; Helmholtz-Zentrum München (HMGU), Institute of Radiation Protection, Neuherberg, GERMANY
Wissmann, Frank; 6.4, Ionenbeschleuniger und Referenzstrahlungsfelder, PTB-Braunschweig
Quelle/Jahr (2012), 173, 61 S.
Schriftenreihe Radiation protection: 173
ISBN 978-92-79-27036-9
DOI
Berichtsnummer MJ-XA-12-003-EN-C
Verlag Luxembourg: Office for Official Publ. of the Europ. Communities
Zusammenfassung The aim of this report is to compare the doses and dose rates calculated by various codes assessing radiation exposure of aircraft crew due to cosmic radiation. Some of the codes are used routinely for radiation protection purposes while others are purely for scientific use. The calculations were done using a set of representative, real flight routes around the globe. The results are presented in an anonymous way. This comparison is of major importance since a real determination of effective dose is not possible and, therefore, the different methods used to evaluate effective doses can be compared. Eleven codes have been used in this comparison exercise organised by EURADOS on harmonization of aircrew dosimetry practices in European countries. Some of these codes are based on simulations of the secondary field of cosmic radiation by Monte Carlo techniques; other use analytical solutions of the problem, while still others are mainly based on a fit to experimental data. The overall agreement between the codes, however, is better than ±20 % from the median.

Zitierung

Bottollier-Depois, J. F., Beck, P., Latocha, M., Mares, V., Matthiä, D., Rühm, W., & Wissmann, F. (2012). Comparison of codes assessing radiation exposure of aircraft crew due to galactic cosmic radiation (Report No. MJ-XA-12-003-EN-C). Luxembourg: Office for Official Publ. of the Europ. Communities. https://doi.org/10.2768/22100