| Zugriffsnummer | 28703 |
| Dokumenttyp | Bericht |
| Peer Review | unbekannt |
| Sprache | Englisch |
| Titel | EURAMET key comparison L-K6, CMM2-D Artifact: Ball plate : final report |
| Autor(in); Institution |
Zeleny, Vit; Czech Metrology Institute (CMI), Praha, CZECH REPUBLIC
Chiffre, Leonardo de; DTU, Manufacturing Engineering and Management Produktionstorvet, Lyngby, DENMARK
Tikka, Heikki; Tampere University of Technology (TUT), Institute of Production Engineering, Tampere, FINLAND
Jusko, Otto; 5.3, Koordinatenmesstechnik, PTB-Braunschweig
Banreti, Edit; National Office of Measures(OMH), Budapest, HUNGARY
Turner, Paul; National Metrology Laboratory (NML), Dublin, IRELAND
Bergmans, Rob; VSL Dutch Metrology, Delft, THE NETHERLANDS
Saraiva, Fernanda; Instituto Portugues da Qualidade Laboratorio de Metrologia (IPQ), Caparica, PORTUGAL
Lewis, Andrew; National Physical Laboratory (NPL), Centre for Basic, Thermal and Length Metrology, Teddington, UK
|
| Quelle/Jahr | (2012), 39 S. |
| Availability | [Online only] |
| URL | |
| Freie Schlagworte | ball plate ; calibration ; comparison ; NMI ; intercomparison |
| Zusammenfassung | An intercomparison of ball plate calibrations was conducted. 11 European NMI participated. The data generally well agreed within the stated uncertainties. Therefore the comparison supports the CMC claims of the involved NMIs. |