| Zugriffsnummer | 28146 |
| Dokumenttyp | Bericht |
| Sprache | Englisch |
| Titel | Comparison of codes assessing radiation exposure of aircraft crew due to galactic cosmic radiation |
| Autor(in); Institution |
Bottollier-Depois, J. F.; Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, FRANCE
Beck, P.; Austrian Institute of Technology (AIT), Vienna, AUSTRIA
Latocha, M.; Austrian Institute of Technology (AIT), Vienna, AUSTRIA
Mares, V.; Helmholtz-Zentrum München (HMGU), Institute of Radiation Protection, Neuherberg, GERMANY
Matthiä, D.; Deutsches Zentrum für Luft- und Raumfahrt (DLR), Institute of Aerospace Medicine, Köln, GERMANY
Rühm, W.; Helmholtz-Zentrum München (HMGU), Institute of Radiation Protection, Neuherberg, GERMANY
Wissmann, Frank; 6.4, Ionenbeschleuniger und Referenzstrahlungsfelder, PTB-Braunschweig
|
| Quelle/Jahr | (2012), VIII, 55 S. |
| Schriftenreihe | EURADOS Report: 2012-03 |
| ISBN | 978-3-943701-02-9 |
| URL | |
| Berichtsnummer | EURADOS Report 2012-03 |
| Verlag | Braunschweig: European Radiation Dosimetry Group e. V. |
| Freie Schlagworte | cosmic radiation |
| Zusammenfassung | The aim of this report is to compare the doses and dose rates calculated by various codes assessing radiation exposure of aircraft crew due to cosmic radiation. Some of the codes are used routinely for radiation protection purposes while others are purely for scientific use. The calculations were done using a set of representative, real flight routes around the globe. The results are presented in an anonymous way. This comparison is of major importance since a real determination of effective dose is not possible and, therefore, the different methods used to evaluate effective doses can be compared. Eleven codes have been used in this comparison exercise organised by EURADOS on harmonization of aircrew dosimetry practices in European countries. Some of these codes are based on simulations of the secondary field of cosmic radiation by Monte Carlo techniques; others use analytical solutions of the problem, while still others are mainly based on a fit to experimental data. The overall agreement between the codes, however, ist better than ±20 % from the median. |