Zugriffsnummer 28066
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Time and position sensitive single photon detector for scintillator read-out
Autor(in); Institution
Schössler, S.; RoentDek GmbH, Kelkheim, GERMANY
Bromberger, Benjamin; 6.5, Neutronenstrahlung, PTB-Braunschweig
Brandis, M.; Soreq NRC, Nuclear Physics Division, Yavne, ISRAEL
Schmidt, L. Ph. H.; Johann-Wolfgang Goethe Universität, Institut für Kernphysik, Frankfurt, GERMANY
Tittelmeier, Kai; 6.5, Neutronenstrahlung, PTB-Braunschweig
Czasch, A.; RoentDek GmbH, Kelkheim, GERMANY
Dangendorf, Volker; 6.5, Neutronenstrahlung, PTB-Braunschweig
Jagutzki, O.; RoentDek GmbH, Kelkheim, GERMANY
Quelle/Jahr Journal of Instrumentation: 7 (2012), 1 - 12
Artikelnummer C02048
Availability [online only]
ISSN 1748-0221
DOI
Verlag London: IOP Publ.
Konferenzangaben 2nd International Workshop on Fast Neutron Detectors and Applications, Ein Gedi, 06-11, November, 2011, ISRAEL
Freie Schlagworte Inspection with gamma rays ; Detection of contraband and drugs ; Photon detectors for UV ; Visibile and IR photons ; Neutron radiography
Zusammenfassung We have developed a photon counting detector system for combined neutron and γ radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a microchannel plate photomultiplier concept utilizing image charge coupling to a position- and timesensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy γ radiography method (FNDDER).We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate γ energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).
Kostenfreier Zugang Open Access Hybrid

Zitierung

Schössler, S., Bromberger, B., Brandis, M., Schmidt, L. P. H., Tittelmeier, K., Czasch, A., Dangendorf, V., & Jagutzki, O. (2012). Time and position sensitive single photon detector for scintillator read-out. Journal of Instrumentation, 7, 1–12. https://doi.org/10.1088/1748-0221/7/02/c02048

Exportieren