Zugriffsnummer 28065
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Neutron measurements with Time-Resolved Event-Counting Optical Radiation (TRECOR) detector
Autor(in); Institution
Brandis, M.; Soreq NCR, Nuclear Physics Division, Yavne, ISRAEL
Vartsky, D.; Soreq NCR, Nuclear Physics Division, Yavne, ISRAEL
Dangendorf, Volker; 6.5, Neutronenstrahlung, PTB-Braunschweig
Bromberger, Benjamin; 6.5, Neutronenstrahlung, PTB-Braunschweig
Bar, D.; Soreq NCR, Nuclear Physics Division, Yavne, ISRAEL
Goldberg, M.; Soreq NCR, Nuclear Physics Division, Yavne, ISRAEL
Tittelmeier, Kai; 6.5, Neutronenstrahlung, PTB-Braunschweig
Friedman, E.; Hebrew University of Jerusalem, Racah Institute of Physics, Jerusalem, ISRAEL
Czasch, A.; University of Frankfurt, RoentDek GmbH, Frankfurt, GERMANY
Mardor, I.; Soreq NCR, Nuclear Physics Division, Yavne, ISRAEL
Mor, Ilan; 6.5, Neutronenstrahlung, PTB-Braunschweig
Weierganz, Mathias; 6.5, Neutronenstrahlung, PTB-Braunschweig
Quelle/Jahr Journal of Instrumentation: 7 (2012), 1 - 10
Artikelnummer C04003
Availability [online only]
ISSN 1748-0221
DOI
Verlag London: IOP Publ.
Konferenzangaben 2nd International Workshop on Fast Neutron Detectors and Applications, Ein Gedi, 06-11, November, 2011, Israel
Freie Schlagworte Neutron detectors ; Detection of explosives ; Neutron radiography ; Inspection with gamma rays
Zusammenfassung Results are presented from the latest experiment with a new neutron/gamma detector, a Time-Resolved, Event-Counting Optical Radiation (TRECOR) detector. It is composed of a scintillating fiber-screen converter, bending mirror, lens and Event-Counting Image Intensifier (ECII), capable of specifying the position and time-of-flight of each event. TRECOR is designated for a multipurpose integrated system that will detect Special Nuclear Materials (SNM) and explosives in cargo. Explosives are detected by Fast-Neutron Resonance Radiography, and SNM by Dual Discrete-Energy gamma-Radiography. Neutrons and gamma-rays are both produced in the 11B(d,n+g)12C reaction. The two detection modes can be implemented simultaneously in TRECOR, using two adjacent radiation converters that share a common optical readout. In the present experiment the neutron detection mode was studied, using a plastic scintillator converter. The measurements were performed at the PTB cyclotron, using the 9Be(d,n) neutron spectrum obtained from a thick Be-target at Ed &13 MeV. The basic characteristics of this detector were investigated, including the Contrast Transfer Function (CTF), Point Spread Function (PSF) and elemental discrimination capability.
Kostenfreier Zugang Open Access Hybrid

Zitierung

Brandis, M., Vartsky, D., Dangendorf, V., Bromberger, B., Bar, D., Goldberg, M., Tittelmeier, K., Friedman, E., Czasch, A., Mardor, I., Mor, I., & Weierganz, M. (2012). Neutron measurements with Time-Resolved Event-Counting Optical Radiation (TRECOR) detector. Journal of Instrumentation, 7, 1–10. https://doi.org/10.1088/1748-0221/7/04/c04003

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag