Zugriffsnummer 28049
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Hybrid
Peer Review mit Peer Review
Sprache Englisch
Titel Research and development of a dedicated collimator for 14.2 MeV fast neutrons for imaging using a D-T-generator
Autor(in); Institution
Sabo-Napadensky, I.; Soreq NRC, NDT Department, Yavne, ISRAEL
Weiss-Babai, R.; Soreq NRC, NDT Department, Yavne, ISRAEL
Gayer, A.; Soreq NRC, NDT Department, Yavne, ISRAEL
Vartsky, D.; Soreq NRC, NDT Department, Yavne, ISRAEL
Bar, D.; Soreq NRC, NDT Department, Yavne, ISRAEL
Mor, Ilan; 6.5, Neutronenstrahlung, PTB-Braunschweig; Soreq NRC, ISRAEL
Chacham-Zada, R.; Soreq NRC, NDT Department, Yavne, ISRAEL
Cohen, M.; Soreq NRC, NDT Department, Yavne, ISRAEL
Tamim, N.; Soreq NRC, NDT Department, Yavne, ISRAEL
Quelle/Jahr Journal of Instrumentation: 7 (2012), 1 - 16
Artikelnummer C06005
Availability [online only]
ISSN 1748-0221
DOI
Verlag London: IOP Publ.
Konferenzangaben 2nd International Workshop on Fast Neutron Detectors and Applications, Ein Gedi, 06-11, November, 2011, ISRAEL
Klassifikationscode PACS: 42.79.Ag ; PACS: 42.79.Ls ; PACS: 41.85.Si ; PACS: 42.30.Va
Freie Schlagworte Inspection with neutrons ; Detection of defects ; Neutron detectors ; Neutron radiography
Zusammenfassung One of the main problems in neutron imaging is the scattered radiation that accompanies the direct neutrons that reach the imaging detectors and affect the image quality. We have developed a dedicated collimator for 14.2MeV fast neutrons. The collimator optimizes the amount of scattered radiation to primary neutrons that arrive at the imaging plane. We have used different materials within the collimator in order to lower the scattered radiation that arrives at the scanned object. The image quality and the signal to noise ratios that are measured show that a mixture of BORAX (Na2B4O7 · 10H2O) and water in the experimental beam collimator give the best results. We have used GEANT4 to simulate the collimator performance, the simulations predict the optimized material looking on the ratios of the scattered to primary neutrons that contribute in the detector. We present our experimental setup, report the results of the experimental and related simulation studies with neutrons beam generated by a 14.2MeV D-T neutron generator.
Kostenfreier Zugang Open Access Hybrid

Zitierung

Sabo-Napadensky, I., Weiss-Babai, R., Gayer, A., Vartsky, D., Bar, D., Mor, I., Chacham-Zada, R., Cohen, M., & Tamim, N. (2012). Research and development of a dedicated collimator for 14.2 MeV fast neutrons for imaging using a D-T-generator. Journal of Instrumentation, 7, 1–16. https://doi.org/10.1088/1748-0221/7/06/c06005

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag