| Zugriffsnummer | 27874 |
| Dokumenttyp | Zeitschriftenartikel |
| Sprache | Englisch |
| Titel | Pulse energy measurement at the hard x-ray laser in Japan |
| Autor(in); Institution |
Kato, M.; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, JAPAN, RIKEN SPring-8 Center, Hyogo, JAPAN
Tanaka, T.; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, JAPAN, RIKEN SPring-8 Center, Hyogo, JAPAN
Kurosawa, T.; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, JAPAN
Saito, N.; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, JAPAN, RIKEN SPring-8 Center, Hyogo, JAPAN
Richter, Mathias; 7.1, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Sorokin, A.A.; RIKEN SPring-8 Center, Hyogo, JAPAN, Deutsches Elektronen-Synchrotron (DESY), Hamburg, GERMANY, Ioffe Physico-Technical Institute, RAS, St. Petersburg, RUSSIA
Tiedtke, K.; RIKEN SPring-8 Center, Hyogo, JAPAN, Deutsches Elektronen-Synchrotron, Hamburg, GERMANY
Kudo, T.; RIKEN SPring-8 Center, Hyogo, JAPAN, Japan Synchrotron Radiation Research Institute, Hyogo, JAPAN
Tono, K.; Japan Synchrotron Radiation Research Institute, Hyogo, JAPAN
Yabashi, M.; RIKEN SPring-8 Center, Hyogo, JAPAN, Japan Synchrotron Radiation Research Institute, Hyogo, JAPAN
Ishikawa, T.; RIKEN SPring-8 Center, Hyogo, JAPAN
|
| Quelle/Jahr | Applied Physics Letters: 101 (2012), 2, 023503-1 - 023503-4 |
| ISSN | 0003-6951 (PRINT) ; 1077-3118 (ONLINE) |
| DOI | |
| Verlag | Melville, NY: AIP |
| Klassifikationscode | PACS: 42.55.Vc ; PACS: 84.37.+q ; PACS: 06.20.fb ; PACS: 41.60.Cr |
| Zusammenfassung | The pulse energies of a free electron laser have accurately been measured in the hard x-ray spectral range. In the photon energy regime from 4.4 keV to 16.8 keV, pulse energies up to 100 .mycro.J were obtained at the hard x-ray laser facility SACLA (SPring-8 Ångstrom Compact free-electron LAser). Two independent methods, using a cryogenic radiometer and a gas monitor detector, were applied and agreement within 3.3% was achieved. Based on our validated pulse energy measurement, a SACLA online monitor detector could be calibrated for all future experiments. |
Zitierung
Kato, M., Tanaka, T., Kurosawa, T., Saito, N., Richter, M., Sorokin, A., Tiedtke, K., Kudo, T., Tono, K., Yabashi, M., & Ishikawa, T. (2012). Pulse energy measurement at the hard x-ray laser in Japan. Applied Physics Letters, 101(2), 023503-1–023503-4. https://doi.org/10.1063/1.4733354