Zugriffsnummer 27693
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Improved performance of the ECCS experiment at PTB
Autor(in); Institution
Scherer, Hansjörg; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Camarota, Benedetta; 2.6, Elektrische Quantenmetrologie, PTB-Braunschweig
Keller, Mark W.; National Institute of Standards and Technology (NIST), Boulder, Colo., USA
Lotkhov, Sergey V.; 2.4, Quantenelektronik, PTB-Braunschweig
Quelle/Jahr 2012 Conference on Precision Electromagnetic Measurements digest:(2012), 350 - 351
Availability [CD-ROM] ; file name: 176.pdf
Konferenzangaben 28th Conference on Precision Electromagnetic Measurements (CPEM) 2012, Washington, DC, 01-06, July, 2012, USA
Freie Schlagworte Capacitance measurement ; data analysis ; measurement standards ; measurement uncertainty ; precision measurements ; nanoscale devices ; single electron devices
Zusammenfassung Recent improvements on the ECCS experiment at PTB are reported. A 5-junction single-electron R-pump is shown to shuttle electrons with a relative transfer error of 5 ×10-8. Moreover, the relative uncertainty of the setup for the cryogenic capacitor voltage measurement has been reduced to urel <10-9. Further perspectives related to data evaluation and analysis on the ECCS experiment is also discussed.

Zitierung

Scherer, H., Camarota, B., Keller, M. W., & Lotkhov, S. V. (2012). Improved performance of the ECCS experiment at PTB. 28th Conference on Precision Electromagnetic Measurements (CPEM) 2012, Washington, DC, 01-06, July, 2012, USA.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag