Titel Are brain currents detectable by means of low-field NMR? A phantom study
Autor(in); Institution
Höfner, Nora; 8.2, Biosignale, PTB-Berlin
Albrecht, Hans-Helge; 8.2, Biosignale, PTB-Berlin
Cassará, A.; Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Rome, ITALY, Dip. di Fisica, Università di Roma “La Sapienza”, Rome, ITALY
Curio, G.; Department of Neurology, Campus Benjamin Franklin, Charité-Universitätsmedizin, Berlin, GERMANY
Hartwig, Stefan; 8.2, Biosignale, PTB-Berlin
Haueisen, J.; Institute of Biomedical Engineering and Informatics, Ilmenau University of Technology, Ilmenau, GERMANY, Biomagnetic Centre, Department of Neurology, University Hospital Jena, Jena, GERMANY
Hilschenz, Ingo; 8.2, Biosignale, PTB-Berlin
Körber, Rainer; 8.2, Biosignale, PTB-Berlin
Martens, S.; Institute of Biomedical Engineering and Informatics, Ilmenau University of Technology, Ilmenau, GERMANY
Scheer, Hans-Jürgen; 8.2, Biosignale, PTB-Berlin
Voigt, Jens; 8.2, Biosignale, PTB-Berlin
Trahms, Lutz; 8.2, Biosignale, PTB-Berlin
Burghoff, Martin; 8.2, Biosignale, PTB-Berlin
Quelle/Jahr Magnetic Resonance Imaging: 29 (2011), 10, 1365 - 1373
ISSN 0730-725X (PRINT)
DOI
Verlag New York, NY: Elsevier
Freie Schlagworte Neuronal currents ; Saline dipole phantom ; Low-Field NMR ; MEG
Zusammenfassung A number of different methods have been developed in order to detect the spreading of neuronal currents by means of noninvasive imaging techniques. However, all of these are subjected to limitations in the temporal or spatial resolution. A new approach of neuronal current detection is based on the use of low-field nuclear magnetic resonance (LF-NMR) that records brain activity directly. In the following, we describe a phantom study in order to assess the feasibility of neuronal current detection using LF-NMR. In addition to that, necessary preliminary subject studies examining somatosensory evoked neuronal currents are presented. During the phantom study, the influences of two different neuronal time signals on 1H-NMR signals were observed. The measurements were carried out by using a head phantom with an integrated current dipole to simulate neuronal activity. Two LF-NMR methods based on a DC and an AC (resonant) mechanism were utilized to study the feasibility of detecting both types of magnetic brain signals. Measurements were made inside an extremely magnetically shielded room by using a superconducting quantum interference device magnetometer system. The measurement principles were validated applying currents of higher intensity than those typical of the neuronal currents. Through stepwise reduction of the amplitude of the current dipole strength, the resolution limits of the two measuring procedures were found. The results indicate that it is necessary to improve the signal-to-noise ratio of the measurement system by at least a factor of 38 in order to detect typical human neuronal activity directly by means of LF-NMR. In addition to that, ways of achieving this factor are discussed.

Zitierung

Höfner, N., Albrecht, H.-H., Cassará, A., Curio, G., Hartwig, S., Haueisen, J., Hilschenz, I., Körber, R., Martens, S., Scheer, H.-J., Voigt, J., Trahms, L., & Burghoff, M. (2011). Are brain currents detectable by means of low-field NMR? A phantom study. Magnetic Resonance Imaging, 29(10), 1365–1373. https://doi.org/10.1016/j.mri.2011.07.009