Zugriffsnummer 26850
Dokumenttyp Zeitschriftenartikel
Peer Review unbekannt
Sprache Englisch
Titel The 87Sr optical frequency standard at PTB
Autor(in); Institution
Falke, Stephan; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Schnatz, Harald; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Vellore Winfred, Joseph Sundar Raaj; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Middelmann, Thomas; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Vogt, Stefan; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Weyers, Stefan; 4.4, Zeit und Frequenz, PTB-Braunschweig
Lipphardt, Burghard; 4.4, Zeit und Frequenz, PTB-Braunschweig
Grosche, Gesine; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Riehle, Fritz; 4, Optik, PTB-Braunschweig
Sterr, Uwe; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Lisdat, Christian; 4.3, Quantenoptik und Längeneinheit, PTB-Braunschweig
Quelle/Jahr Metrologia: 48 (2011), 5, 399 - 407
ISSN 0026-1394
DOI
URL
Verlag Bristol [u.a.]: IOP [u.a.]
Klassifikationscode PACS: 06.20.fb ; PACS: 06.20.fa ; PACS: 06.30.Ft ; PACS: 37.10.De ; PACS: 32.60.+i
Zusammenfassung With 87Sr atoms confined in a one-dimensional optical lattice, the frequency of the optical clock transition 5s2 1S0-5s5p 3P0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a femtosecond-frequency comb against one of Physikalisch-Technische Bundesanstalt (PTB’s) H-masers whose frequency was measured simultaneously by the PTB Cs-fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 × 10-16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as the secondary representation of the second with the currently smallest uncertainty.

Zitierung

Falke, S., Schnatz, H., Vellore Winfred, J. S. R., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., & Lisdat, C. (2011). The ⁸⁷Sr optical frequency standard at PTB. Metrologia, 48(5), 399–407. https://doi.org/10.1088/0026-1394/48/5/022