Zugriffsnummer 26423
Dokumenttyp Zeitschriftenartikel
Peer Review unbekannt
Sprache Englisch
Titel Frequency domain multiplexed readout of TES detector arrays with baseband feedback
Autor(in); Institution
den Hartog, Roland; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Beyer, Jörn; 7.5, Kryo- und Vakuumphysik, PTB-Berlin
Boersma, Dick; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Bruijn, Marcel; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Gottardi, Luciano; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Hoevers, Henk; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Hou, Rui; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Kiviranta, Mikko; VTT, The Technology Reseach Centre of Finland, Espoo, FINLAND
de Korte, Piet; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
van der Kuur, Jan; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
van Leeuwen, Bert-Joost; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Lindemann, Mark; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Nieuwenhuizen, Ad; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Quelle/Jahr IEEE Transactions on Applied Superconductivity: 21 (2011), 3, 289 - 293
ISSN 1051-8223
DOI
Verlag New York, NY: IEEE
Freie Schlagworte Terms-Bolometers ; FDM ; IXO ; microcalorimeters ; SPICA ; SQUID read-out electronics ; TES
Zusammenfassung SRON is developed an electronic read-out system for an array of Transition-Edge Sensors (TES) which combines the techniques of Frequency Domain Multiplexing (FDM) with Base-Band FeedBack (BBFB). Its potential astronomical applications are in the read-out of soft X-ray microcalorimeters of the XMS instrument on the International X-ray Observatory (IXO) and the far-IR bolometers of the SAFARI instrument on the Japanese-European mission SPICA. In this paper we focus on the experimental verification of the system, demonstrating for 16 pixels that simultaneous read-out does not degrade the noise performance, and that crosstalk between pixels is close to the requirements for IXO. A detailed analysis of the BBFB system is presented, identifying its limitations and routes for improvement to the levels required for implementation on both missions.

Zitierung

den Hartog, R., Beyer, J., Boersma, D., Bruijn, M., Gottardi, L., Hoevers, H., Hou, R., Kiviranta, M., de Korte, P., van der Kuur, J., van Leeuwen, B.-J., Lindemann, M., & Nieuwenhuizen, A. (2011). Frequency domain multiplexed readout of TES detector arrays with baseband feedback. IEEE Transactions on Applied Superconductivity, 21(3), 289–293. https://doi.org/10.1109/tasc.2010.2101998