| Zugriffsnummer | 26423 |
| Dokumenttyp | Zeitschriftenartikel |
| Peer Review | unbekannt |
| Sprache | Englisch |
| Titel | Frequency domain multiplexed readout of TES detector arrays with baseband feedback |
| Autor(in); Institution |
den Hartog, Roland; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Beyer, Jörn; 7.5, Kryo- und Vakuumphysik, PTB-Berlin
Boersma, Dick; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Bruijn, Marcel; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Gottardi, Luciano; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Hoevers, Henk; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Hou, Rui; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Kiviranta, Mikko; VTT, The Technology Reseach Centre of Finland, Espoo, FINLAND
de Korte, Piet; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
van der Kuur, Jan; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
van Leeuwen, Bert-Joost; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Lindemann, Mark; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
Nieuwenhuizen, Ad; SRON National Institute for Space Research, Utrecht, THE NETHERLANDS
|
| Quelle/Jahr | IEEE Transactions on Applied Superconductivity: 21 (2011), 3, 289 - 293 |
| ISSN | 1051-8223 |
| DOI | |
| Verlag | New York, NY: IEEE |
| Freie Schlagworte | Terms-Bolometers ; FDM ; IXO ; microcalorimeters ; SPICA ; SQUID read-out electronics ; TES |
| Zusammenfassung | SRON is developed an electronic read-out system for an array of Transition-Edge Sensors (TES) which combines the techniques of Frequency Domain Multiplexing (FDM) with Base-Band FeedBack (BBFB). Its potential astronomical applications are in the read-out of soft X-ray microcalorimeters of the XMS instrument on the International X-ray Observatory (IXO) and the far-IR bolometers of the SAFARI instrument on the Japanese-European mission SPICA. In this paper we focus on the experimental verification of the system, demonstrating for 16 pixels that simultaneous read-out does not degrade the noise performance, and that crosstalk between pixels is close to the requirements for IXO. A detailed analysis of the BBFB system is presented, identifying its limitations and routes for improvement to the levels required for implementation on both missions. |
Zitierung
den Hartog, R., Beyer, J., Boersma, D., Bruijn, M., Gottardi, L., Hoevers, H., Hou, R., Kiviranta, M., de Korte, P., van der Kuur, J., van Leeuwen, B.-J., Lindemann, M., & Nieuwenhuizen, A. (2011). Frequency domain multiplexed readout of TES detector arrays with baseband feedback. IEEE Transactions on Applied Superconductivity, 21(3), 289–293. https://doi.org/10.1109/tasc.2010.2101998