Zugriffsnummer 26413
Dokumenttyp Konferenzartikel in Zeitschrift Open Access Gold
Peer Review mit Peer Review
Sprache Englisch
Titel Verification of scattering parameter measurements in waveguides up to 325 GHz including highly-reflective devices
Autor(in); Institution
Schrader, Thorsten; 2.2, Hochfrequenz und Felder, PTB-Braunschweig
Kuhlmann, Karsten; 2.2, Hochfrequenz und Felder, PTB-Braunschweig
Dickhoff, Robert; 2.2, Hochfrequenz und Felder, PTB-Braunschweig
Dittmer, Jan; 2.2, Hochfrequenz und Felder, PTB-Braunschweig
Hiebel, M.; Rohde und Schwarz, Munich, GERMANY
Quelle/Jahr Kleinheubacher Berichte 2010. Advances in Radio Science: 9 (2011), 9 - 17
Availability [online only]
ISSN 1684-9973
DOI
URL
Verlag Göttingen: Copernicus Publications
Konferenzangaben Kleinheubacher Tagung 2010, Miltenberg, 04-06, Oktober, 2010, Deutschland
Zusammenfassung Radio-frequency (RF) scattering parameters (S-parameters) play an important role to characterise RF signal transmission and reflection of active and passive devices such as transmission lines, components, and small-signal amplifiers. Vector network analysers (VNAs) are employed as instrumentation for such measurements. During the last years, the upper frequency limit of this instrumentation has been extended up to several hundreds of GHz for waveguide measurements. Calibration and verification procedures are obligatory prior to the VNA measurement to achieve accurate results and/or to obtain traceability to the International System of Units (SI). Usually, verification is performed by measuring well-matched devices with known S-parameters such as attenuators or short precision waveguide sections (shims). In waveguides, especially above 110 GHz, such devices may not exist and/or are not traceably calibrated. In some cases, e.g. filter networks, the devices under test (DUT) are partly highly reflective. This paper describes the dependency of the S-parameters a) on the calibration procedure, b) on the applied torque to the flange screws during the mating process of the single waveguide elements. It describes further c) how highly-reflective devices (HRD) can be used to verify a calibrated VNA, and d) how a measured attenuation at several hundreds of GHz can be substituted by a well-known coaxial attenuation at 279 MHz, the intermediate frequency (IF) of the VNA, to verify the linearity. This work is a contribution towards traceability and to obtain knowledge about the measurement uncertainty of VNA instrumentation in the millimetre-wave range.
Kostenfreier Zugang Open Access Gold
Rechteinformation CC BY 3.0 ; Creative Commons Attribution 3.0 License

Zitierung

Schrader, T., Kuhlmann, K., Dickhoff, R., Dittmer, J., & Hiebel, M. (2011). Verification of scattering parameter measurements in waveguides up to 325 GHz including highly-reflective devices. Advances in Radio Science, 9, 9–17. https://doi.org/10.5194/ars-9-9-2011

Exportieren

PTB-Publica Menü