Zugriffsnummer 25697
Dokumenttyp Zeitschriftenartikel
Peer Review unbekannt
Sprache Englisch
Titel Air kerma to dose equivalent conversion coefficients not included in ISO 4037-3
Autor(in); Institution
Behrens, Rolf; 6.3, Strahlenschutzdosimetrie, PTB-Braunschweig
Quelle/Jahr Radiation Protection Dosimetry: 147 (2011), 3, 373 - 379
ISSN 0144-8420
DOI
Verlag Oxford: Oxford University Press
Zusammenfassung The International Organization for Standardization (ISO) has issued a standard series on photon reference radiation qualities (ISO 4037). In this work, conversion coefficients from air kerma to dose equivalent quantities not included in ISO 4037-3 are supplied for the following quantities: for Hp(0.07) for X and gaama radiation qualities for the rod, the pillar and the slab phantom and for Hp(3) for X and gamma radiation qualities for the slab phantom. In addition, an overview of conversion coefficients suggested for use for all quantities relevant in radiation protection is provided.

Zitierung

Behrens, R. (2011). Air kerma to dose equivalent conversion coefficients not included in ISO 4037-3. Radiation Protection Dosimetry, 147(3), 373–379. https://doi.org/10.1093/rpd/ncq459

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag