Zugriffsnummer 25375
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Simulations of Tx-SENSE performance of a 4 channel decoupled loop array for cardiac imaging at 7T [poster]
Autor(in); Institution
Seifert, Frank; 8.1, Medizinische Messtechnik, PTB-Berlin; Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular, Berlin, GERMANY
Lindel, Tomasz D.; 8.1, Medizinische Messtechnik, PTB-Berlin; Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular, Berlin, GERMANY
Kühne, André; 8.1, Medizinische Messtechnik, PTB-Berlin; Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular, Berlin, GERMANY
Waiczies, Helmar; 8.1, Medizinische Messtechnik, PTB-Berlin; Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular, Berlin, GERMANY
Renz, W.; Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular, Berlin, GERMANY; Siemens Healthcare, Erlangen, GERMANY
Ittermann, Bernd; 8.1, Medizinische Messtechnik, PTB-Berlin; Berlin Ultrahigh Field Facility, Max-Delbrück-Center for Molecular, Berlin, GERMANY
Quelle/Jahr Proceedings International Society for Magnetic Resonance in Medicine: 18 (2010), 1 S.
Availability [CD-ROM] ; file name: 3813_5506.pdf
ISSN 1545-4428
Konferenzangaben ISMRM-ESMRMB Joint Annual Meeting ; ISMRM 18th Scientific Meeting, Stockholm, 01-07, May, 2010, Schweden
Zusammenfassung Transmit (Tx)-SENSE performance depends crucially on the reliable knowledge of the B1(+)-maps of the transmit coil elements. To speed up the whole imaging procedure true B1(+)-mapping is often avoided by using the virtual reference approach. This virtual reference is constructed from the sum-ofsquare images of all transmit and receive channels and is assumed to be almost homogeneous. Unfortunately, at ultra-high fields this assumption is questionable, especially in body imaging. As a result, it may no longer be possible to achieve the desired excitation patterns. In order to estimate the experimental outcome of Tx-SENSE based zoomed cardiac imaging at 7T we performed FDTD simulations on a computer model of the human body. From simulated B1(+)-and B1(-)-maps of a home-built 4-channel TX/RX torso coil, the virtual-reference-based transmit sensitivity maps can easily be derived. This way, two complete simulations of a Tx-SENSE experiment can be compared: one based on the virtual reference approximation and one using the true B1(+)-maps.

Zitierung

Seifert, F., Lindel, T. D., Kühne, A., Waiczies, H., Renz, W., & Ittermann, B. (2010). Simulations of Tx-SENSE performance of a 4 channel decoupled loop array for cardiac imaging at 7T [poster]. ISMRM-ESMRMB Joint Annual Meeting ; ISMRM 18th Scientific Meeting, Stockholm, 01-07, May, 2010, Schweden.