| Zugriffsnummer | 25006 |
| Dokumenttyp | Zeitschriftenartikel |
| Peer Review | unbekannt |
| Sprache | Englisch |
| Titel | Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer |
| Autor(in); Institution |
Kato, Masahiro; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba, JAPAN; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
Saito, Norio; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba, JAPAN, RIKEN; XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
Tiedtke, Kai; Deutsches RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN; Elektronen-Synchrotron, DESY, Hamburg, GERMANY
Juranic, Pavle N.; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN; Elektronen-Synchrotron, DESY, Hamburg, GERMANY
Sorokin, Andrei A.; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN; Elektronen-Synchrotron, DESY, Hamburg, GERMANY; DESY, Hamburg, GERMANY
Richter, Mathias; 7.1, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Morishita, Yuichiro; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba, JAPAN
Tanaka, Takahiro; National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba, JAPAN; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
Jastrow, Ulf; Deutsches Elektronen-Synchrotron, DESY, Hamburg, GERMANY
Kroth, Udo; 7.2, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Schöppe, Hendrik; 7.2, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Nagasono, Mitsuru; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
Yabashi, Makina; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
Tono, Kensuke; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
Togashi, Tadashi; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN; Japan Synchrotron Radiation Research Institute, Sayo, Hyogo, JAPAN
Kimura, Hiroaki; Japan Synchrotron Radiation Research Institute, Sayo, Hyogo, JAPAN
Ohashi, Haruhiko; Japan Synchrotron Radiation Research Institute, Sayo, Hyogo, JAPAN
Ishikawa, Tetsuya; RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo, JAPAN
|
| Quelle/Jahr | Metrologia: 47 (2010), 5, 518 - 521 |
| ISSN | 0026-1394 |
| DOI | |
| Verlag | Bristol [u.a.]: IOP Publishing |
| Klassifikationscode | PACS: 07.20.Mc ; PACS: 41.60.Cr |
| Zusammenfassung | The absolute single-shot pulse energy of the SPring 8 extreme ultraviolet (EUV) free electron laser (FEL) was measured using a cryogenic radiometer with a relative standard uncertainty of 3%. The temperature change of the cavity in the cryogenic radiometer caused by an incident FEL pulse was determined using a lock-in amplifier and an ac Wheatstone bridge. The measured pulse energies were compared with a gas-monitor detector developed by Physikalisch-Technische Bundesanstalt/Deutsches Elektronen-Synchrotron/Ioffe Physico-Technical Institute (Ioffe) at a wavelength of 51.3 nm at the SPring-8 EUV-FEL in a shot-to-shot mode. The pulse energies measured using the two detectors agree within 2.0%. |
Zitierung
Kato, M., Saito, N., Tiedtke, K., Juranic, P. N., Sorokin, A. A., Richter, M., Morishita, Y., Tanaka, T., Jastrow, U., Kroth, U., Schöppe, H., Nagasono, M., Yabashi, M., Tono, K., Togashi, T., Kimura, H., Ohashi, H., & Ishikawa, T. (2010). Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer. Metrologia, 47(5), 518–521. https://doi.org/10.1088/0026-1394/47/5/002