Zugriffsnummer 24992
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel A new soft x-ray autocorrelator - direct evaluation of the temporal properties of FEL pulses at 24 nm
Autor(in); Institution
Mitzner, R.; HZB, Berlin, GERMANY
Siemer, B.; Physikalisches Institut, WWU, München, GERMANY
Roling, S.; Physikalisches Institut, WWU, München, GERMANY
Wöstmann, M.; Physikalisches Institut, WWU, München, GERMANY
Noll, T.; HZB, Berlin, GERMANY
Siewert, F.; HZB, Berlin, GERMANY
Sorokin, Andrei A.; DESY, Hamburg, GERMANY
Richter, Mathias; 7.1, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Tiedtke, K.; DESY, Hamburg, GERMANY
Zacharias, H.; Physikalisches Institut, WWU, München, GERMANY
Quelle/Jahr SRI 2009 : 10th International Conference on Synchrotron Radiation Instrumentation:(2010), 19 - 22
Schriftenreihe AIP Conference Proceedings: 1234
Availability [CD-ROM] ; file name: 19_1.pdf
ISBN 978-0-7354-0782-4
DOI
Verlag Melville, NY: American Inst. of Physics
Konferenzangaben 10th Intenational Conference on Synchrotron Radiation Instrumentation, Melbourne, 27 September-2 October 2009, Australia
Klassifikationscode PACS: 41.60 Cr ; PACS: 42.25.Kb ; PACS: 42.25.Hz ; PACS: 32.80.Fb
Freie Schlagworte FEL ; VUV ; soft x-ray ; coherence ; pulse length ; autocorrelation
Zusammenfassung To provide two jitter-free soft x-ray pulses for femtosecond x-ray pump and probe experiments a split and delay unit (autocorrelator) has been constructed for the VUV - FEL in Hamburg (FLASH). Here we report experiments applying this autocorrelator to examine the average temporal properties of FEL pulses delivered from FLASH at 24 nm (51.8 eV). In a linear autocorrelation experiment the spatio-temporal coherence properties are measured for both the first and the third harmonic of the FEL pulses. Furthermore, we report on the first evaluation of the pulse length from the time-resolved observation of doubly charged helium ions produced by direct two-photon double ionization at 24 nm. In summary the determination of the longitudinal pulse parameter of FLASH at 24 nm to 6 fs and 29 ± 5 fs for the coherence time and the pulse length (FWHM) respectively proofs the autocorrelator as a valuable tool for time resolved two pulse X-ray experiments.

Zitierung

Mitzner, R., Siemer, B., Roling, S., Wöstmann, M., Noll, T., Siewert, F., Sorokin, A. A., Richter, M., Tiedtke, K., & Zacharias, H. (2010). A new soft x-ray autocorrelator - direct evaluation of the temporal properties of FEL pulses at 24 nm. 10th Intenational Conference on Synchrotron Radiation Instrumentation, Melbourne, 27 September-2 October 2009, Australia. https://doi.org/10.1063/1.3463172

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag