Zugriffsnummer 24941
Dokumenttyp Konferenzartikel
Peer Review unbekannt
Sprache Englisch
Titel Quantum efficiency measurements of eROSITA pnCCDs
Autor(in); Institution
Ebermayer, S.; MPI Semiconductor Laboratory, Munic, GERMANY
Andritschke, R.; MPI Semiconductor Laboratory, Munic, GERMANY
Elbs, J.; MPI Semiconductor Laboratory, Munic, GERMANY
Meidinger, N.; MPI Semiconductor Laboratory, Munic, GERMANY
Strüder, L.; MPI Semiconductor Laboratory, Munic, GERMANY
Hartmann, R.; MPI Semiconductor Laboratory, Munic, GERMANY, PNSensor GmbH, Munic, GERMANY
Gottwald, Alexander; 7.2, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Krumrey, Michael; 7.1, Röntgenmesstechnik mit Synchrotronstrahlung, PTB-Berlin
Scholze, Frank; 7.2, Radiometrie mit Synchrotronstrahlung, PTB-Berlin
Quelle/Jahr High Energy, Optical, and Infrared Detectors for Astronomy IV:(2010), 77420U-1 - 77420U-10
Schriftenreihe Proceedings of SPIE: 7742
Herausgeber(in)
Holland, Andrew D.
Dorn, David A.
ISSN 0277-786X
ISBN 978-0-8194-8232-7
DOI
Verlag Bellingham, Wash.: SPIE
Konferenzangaben Astronomical Instrumentation, San Diego, 27 June - 6 July, 2010, USA
Freie Schlagworte pnCCD ; eROSITA ; quantum efficiency ; detector response ; entrance window
Zusammenfassung For the eROSITA X-ray telescope, which is planned to be launched in 2012, detectors were developed and fabricated at the MPI Semiconductor Laboratory. The fully depleted, back-illuminated pnCCDs have an ultrathin pn-junction to improve the low-energy X-ray response function and quantum efficiency. The device thickness of 450 μm is fully sensitive to X-ray photons yielding high quantum efficiency of more than 90% at photon energies of 10 keV. An on-chip filter is deposited on top of the entrance window to suppress visible and UV light which would interfere with the X-ray observations. The pnCCD type developed for the eROSITA telescope was characterized in terms of quantum efficiency and spectral response function. The described measurements were performed in 2009 at the synchrotron radiation sources BESSY II and MLS as cooperation between the MPI Semiconductor Laboratory and the Physikalisch-Technische Bundesanstalt (PTB). Quantum efficiency measurements over a wide range of photon energies from 3 eV to 11 keV as well as spectral response measurements are presented. For X-ray energies from 3 keV to 10 keV the quantum efficiency of the CCD including on-chip filter is shown to be above 90% with an attenuation of visible light of more than five orders of magnitude. A detector response model is described and compared to the measurements.

Zitierung

Ebermayer, S., Andritschke, R., Elbs, J., Meidinger, N., Strüder, L., Hartmann, R., Gottwald, A., Krumrey, M., & Scholze, F. (2010). Quantum efficiency measurements of eROSITA pnCCDs. Astronomical Instrumentation, San Diego, 27 June - 6 July, 2010, USA. https://doi.org/10.1117/12.856939