| Zugriffsnummer | 24893 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | Simple methods for alignment of line distance sensor arrays |
| Autor(in); Institution |
Bremer, Holger; 4.2, Bild- und Wellenoptik, PTB-Braunschweig; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Schmähling, Franko; 4.2, Bild- und Wellenoptik, PTB-Braunschweig; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Elster, Clemens; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Krey, Stefan; TRIOPTICS, Wedel, GERMANY
Ruprecht, Aiko; TRIOPTICS, Wedel, GERMANY
Schulz, Michael; 4.2, Bild- und Wellenoptik, PTB-Braunschweig
Stavridis, Manuel; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Wiegmann, Axel; 4.2, Bild- und Wellenoptik, PTB-Braunschweig
|
| Quelle/Jahr | Optical micro- and nanometrology III:(2010), 77181M-1 - 77181M-10 |
| Schriftenreihe | Proceedings of SPIE: 7718 |
| Herausgeber(in) |
Gorecki, Christophe
|
| ISBN | 978-0-8194-8191-7 |
| DOI | |
| Verlag | Bellingham, Wash.: SPIE |
| Konferenzangaben | Conference on Optical Micro- and Nanometrology III, Brussels, 13-16, April, 2010, Belgium |
| Zusammenfassung | In dimensional nano- and micrometrology, single sensors are often combined into an array of sensors to enable faster measurements by utilizing parallel data acquisition. If combined with appropriate scanning techniques, the use of sensor arrays additionally facilitates the estimation and correction of systematic sensor errors and, thus, enables more accurate measurements. To exploit these options, the arrays have to be aligned carefully with respect to the scanning direction, and, in addition, the lateral distances between the sensors have to be determined with sufficient accuracy. This presentation describes a method to align an optical distance sensor array parallel to the direction of a linear translation stage, which is used to scan the specimen under test, and it describes a method to evaluate and determine the sensor distances with high accuracy. Alignment is a multi step procedure: The first step is to orientate a step edge profile perpendicular to the scanning direction of the sensor using an M-array and an auxiliary CCD camera. In a second step, the line sensor array is scanned across the edge using different rotation angles of the sensor. The positions where the different sensors cross the edge are evaluated to obtain the sensor orientation relative to the scanning direction, the distances between the sensors, and their transversal displacements. We will show experimental data obtained with an optical line sensor array of three single sensors. The measurements will be compared to simulated data carried out with a virtual experiment programmed at PTB. Relevant error sources are assessed and the limitation of the method is discussed. |
Zitierung
Bremer, H., Schmähling, F., Elster, C., Krey, S., Ruprecht, A., Schulz, M., Stavridis, M., & Wiegmann, A. (2010). Simple methods for alignment of line distance sensor arrays. Conference on Optical Micro- and Nanometrology III, Brussels, 13-16, April, 2010, Belgium. https://doi.org/10.1117/12.854266