Zugriffsnummer 24734
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Field calibration of dosemeters used for routine measurements at flight altitudes
Autor(in); Institution
Wissmann, Frank; 6.4, Ionenbeschleuniger und Referenzstrahlungsfelder, PTB-Braunschweig
Burmeister, S.; CAU, Institut für Experimentelle und Angewandte Physik, Kiel, GERMANY
Dönsdorf, E.; CAU, Institut für Experimentelle und Angewandte Physik, Kiel, GERMANY
Heber, B.; CAU, Institut für Experimentelle und Angewandte Physik, Kiel, GERMANY
Hubiak, M.; DLR, Institute of Aerospace Medicine, Köln, GERMANY
Klages, Thorsten; 6.4, Ionenbeschleuniger und Referenzstrahlungsfelder, PTB-Braunschweig
Langner, Frank; 6.4, Ionenbeschleuniger und Referenzstrahlungsfelder, PTB-Braunschweig
Möller, T.; CAU, Institut für Experimentelle und Angewandte Physik, Kiel, GERMANY
Meier, M.; DLR, Institute of Aerospace Medicine, Köln, GERMANY
Quelle/Jahr Radiation Protection Dosimetry: 140 (2011), 4, 319 - 325
ISSN 0144-8420
DOI
Verlag Oxford: Oxford University Press
Freie Schlagworte Flugdosimetrie ; Kosmische Strahlung ; Strahlenschutz
Zusammenfassung Intercomparisons of dosemeters used in radiation protection are performed routinely in reference radiation fields under well-defined conditions. In the case of the radiation protection of aircrew members, such reference fields either do not exist or they can be partially simulated by accelerator-based fields. Another method is to perform simultaneous measurements on board an aircraft under constant flight conditions, i.e. at defined latitude, longitude and altitude. The intercomparison presented in this work is the second one of its kind. As reference instruments, two types of tissue-equivalent proportional counters (TEPC) were used in comparison with different silicon detector systems. The excellent agreement of the FDOScalc code, which is based on measurements made by PTB during different phases of solar cycle 23 with the TEPC measurements and the results of the preceding project “Coordinated Access to Aircraft for Transnational Environmental Research” (CAATER) even allows the in-field calibration of the Si dosemeters.