Zugriffsnummer 23993
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Power comparator based on-site calibration of isolating current transformers
Autor(in); Institution
Mohns, Enrico; 2.3, Elektrische Energiemesstechnik, PTB-Braunschweig
Latzel, Hans-Georg; 2.3, Elektrische Energiemesstechnik, PTB-Braunschweig
Wittig, Cornelia; 2.3, Elektrische Energiemesstechnik, PTB-Braunschweig
Quelle/Jahr MAPAN - Journal of Metrology Society of India: 24 (2009), 1, 67 - 72
ISSN 0970-3950
URL
Verlag New Delhi: MSI
Zusammenfassung A portable system for on-site calibrations of isolating current transformers in stationary energy meter test systems is described. The uncertainties of the calibration system are in the order of 0.005 % for the ratio error and 0.01 crad for the phase displacement of the current transformer at power frequencies. The power comparator based measurements can be done at test currents from 50 mA to 120 A.

Zitierung

Mohns, E., Latzel, H.-G., & Wittig, C. (2009). Power comparator based on-site calibration of isolating current transformers. MAPAN - Journal of Metrology Society of India, 24(1), 67–72.