Zugriffsnummer 23650
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Highest precision for gas meter calibration worldwide: the high pressure gas calibration facility pigsar with optimized uncertainty
Autor(in); Institution
Mickan, Bodo; 1.4, Gase, PTB-Braunschweig
Kramer, Rainer; 1.4, Gase, PTB-Braunschweig
Müller, Harald; 1.4, Gase, PTB-Braunschweig
Strunck, Volker; 1.4, Gase, PTB-Braunschweig
Vieth, D.; Pigsar, E.ON Ruhrgas AG, Dorsten, GERMANY
Hinze, H.-M.; Pigsar, E.ON Ruhrgas AG, Dorsten, GERMANY
Quelle/Jahr Fluid flow measurement : 7th international symposium:(2009)
Availability [CD-ROM] ; file name: papers\\16.pdf
Herausgeber(in)
North American Fluid Flow Measurement Council
Verlag [s.l.]:
Konferenzangaben 7th International Symposium of Fluid Flow Measurement (ISFFM), Anchorage, Alaska, 12-14, August, 2009, USA
Freie Schlagworte high pressure gas calibration
Zusammenfassung Since 1993 E.ON Ruhrgas operates pigsarTM as one of the leading high-pressure gas calibration facilities worldwide. One major prerequisite for pigsar™'s very low uncertainty is the fact that the German national volumetric primary standard for high-pressure natural gas, the so-called High Pressure Piston Prover (HPPP), property of the Physikalisch-Technische Bundesanstalt, (PTB), is since 1999 an integral part of the infrastructure of pigsar™. During the last few years both PTB and pigsarTM staff have continuously worked on improving the uncertainty and availability of pigsar™. As a major result, the uncertainty of pigsar™ was reduced from initially 0,16% to currently 0,13% in the main operating regime of the facility. New projects already started are aimed at reducing this uncertainty even further down to 0,1%. This paper describes the different measures that have been or will be taken to achieve and verify these improvements.

Zitierung

Mickan, B., Kramer, R., Müller, H., Strunck, V., Vieth, D., & Hinze, H.-M. (2009). Highest precision for gas meter calibration worldwide: the high pressure gas calibration facility pigsar with optimized uncertainty. 7th International Symposium of Fluid Flow Measurement (ISFFM), Anchorage, Alaska, 12-14, August, 2009, USA.