Zugriffsnummer 23602
Dokumenttyp Konferenzartikel in Zeitschrift
Peer Review unbekannt
Sprache Englisch
Titel CCPR-S1 supplementary comparison for spectral radiance in the range of 220 nm to 2500 nm
Autor(in); Institution
Khlevnoy, Boris; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Sapritsky, Victor; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Rougie, Bernard; Bureau National de Métrologie / Institut National de Métrologie (BNM/INM), Paris, FRANCE
Gibson, Charles; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Yoon, Howard; National Institute of Standards and Technology (NIST), Gaithersburg, USA
Gaertner, Arnold; National Research Council of Canada (NRC), Ottawa, CANADA
Taubert, Richard Dieter; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Hartmann, Jürgen; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Quelle/Jahr Metrologia: 46 (2009), 4, S174 - S180
ISSN 0026-1394 (PRINT) ; 1681-7575 (ONLINE)
DOI
Verlag Bristol [u.a.]: Inst. of Physics Publ.
Konferenzangaben NEWRAD 2008, 10th International Conference on New Developments and Applications in Optical Radiometry, Daejeon, 13–16 October 2008, Korea
Zusammenfassung In 1997, the Consultative Committee for Photometry and Radiometry (CCPR) initiated a supplementary comparison of spectral radiance in the wavelength range from 220 nm to 2500 nm (CCPR-S1) using tungsten strip-filament lamps as transfer standards. Five national metrology institutes (NMIs) took part in the comparison: BNM/INM (France), NIST (USA), NRC (Canada), PTB (Germany) and VNIIOFI (Russia), with VNIIOFI as the pilot laboratory. Each NMI provided the transfer lamps that were used to transfer their measurements to the pilot laboratory. The intercomparison sequence began with the participant measurements, then the pilot measurements, followed by a second set of measurements by the participant laboratory. The measurements were carried out from 1998 to 2002, with the final report completed in 2008. This paper presents the descriptions of measurement facilities and uncertainties of the participants, as well as the comparison results that were analysed in accordance with the Guidelines for CCPR Comparisons Report Preparation, and a re-evaluation of the results taking into account the instability of some of the transfer lamps. Excluding a few wavelengths, all participants agree with each other within ± 1.5 %. The disagreement decreases to approximately ± 1.0 % when the anomalous data are excluded from the analysis.

Zitierung

Khlevnoy, B., Sapritsky, V., Rougie, B., Gibson, C., Yoon, H., Gaertner, A., Taubert, R. D., & Hartmann, J. (2009). CCPR-S1 supplementary comparison for spectral radiance in the range of 220 nm to 2500 nm. Metrologia, 46(4), S174–S180. https://doi.org/10.1088/0026-1394/46/4/s08

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag