Zugriffsnummer 23364
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Results of the 2008 TWSTFT calibration of seven european stations
Autor(in); Institution
Bauch, Andreas; 4.4, Zeit und Frequenz, PTB-Braunschweig
Piester, Dirk; 4.4, Zeit und Frequenz, PTB-Braunschweig
Blanzano, B.; Institute of Applied Systems Technology, Joanneum Research Forschungsgesellschaft m.b.H. Graz, AUSTRIA
Koudelka, O.; Institute of Applied Systems Technology, Joanneum Research Forschungsgesellschaft m.b.H. Graz, AUSTRIA
Kroon, E.; Van Swinden Laboratory, Delft, THE NETHERLANDS
Dierikx, E.; Van Swinden Laboratory, Delft, THE NETHERLANDS
Whibberley, P.; National Physical Laboratory (NPL), Time, Quantum And Electromagnetics Team, Teddington, UK
Achkar, J.; LNE-SYRTE, Observatoire de Paris, Time Metrology Group, FRANCE
Rovera, D.; LNE-SYRTE, Observatoire de Paris, Time Metrology Group, FRANCE
Lorini, L.; Istituto Nazionale di Ricerca Metrologica (INRiM), Optics Division, Torino, ITALY
Cordara, F.; Istituto Nazionale di Ricerca Metrologica (INRiM), Optics Division, Torino, ITALY
Schlunegger, C.; METAS, Time and Frequency Laboratory, Bern-Wabern, SWITZERLAND
Quelle/Jahr Proc. European Frequency and Time Forum - IEEE Frequency Control Symposium Joint Conference:(2009), 1209 - 1215
Availability [CD-ROM]
ISBN 978-1-4244-3510-4
Verlag Piscataway, NJ: IEEE
Konferenzangaben European Freqeuncy and Time Forum - IFTF/IEEE-FCS' 09, Besançon, 20-24, April, 2009, France
Freie Schlagworte TWSTFT ; calibration
Zusammenfassung In 2008, seven European institutes participated in a TWSTFT calibration campaign to determine the internal signal delays of their ground stations relative to the portable reference station of Joanneum Research, Graz. In a second step, the calibration values and their uncertainties for time comparisons of 21 links involving the participating institutes were determined. The following results were obtained. The common clock differences between the two TUG stations measured in October 2007, August 2008 and October 2008, respectively, agreed within 0.5 ns, proving the suitability of the traveling station as a reliable and stable traveling reference. After substantial changes in the hardware, the links connecting to NPL and VSL were calibrated with uncertainties slightly exceeding 1 ns and 2 ns, respectively. The so-called TAI links OP-PTB, INRIM-PTB, and METAS-PTB were recalibrated. Despite hardware changes and a change of the satellite in use in early 2008, the calibration values measured this time agreed with the values determined in 2005 and 2006 to well within the calibration uncertainty of slightly above 1 ns.

Zitierung

Bauch, A., Piester, D., Blanzano, B., Koudelka, O., Kroon, E., Dierikx, E., Whibberley, P., Achkar, J., Rovera, D., Lorini, L., Cordara, F., & Schlunegger, C. (2009). Results of the 2008 TWSTFT calibration of seven european stations. European Freqeuncy and Time Forum - IFTF/IEEE-FCS' 09, Besançon, 20-24, April, 2009, France.

Exportieren