Zugriffsnummer 22708
Dokumenttyp Konferenzartikel in Zeitschrift
Sprache Englisch
Titel Camera based investigation of high-temperature fixed-points for radiometric application
Autor(in); Institution
Anhalt, Klaus; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Lindner, Detlef; 4.1, Photometrie und angewandte Radiometrie, PTB-Braunschweig
Krüger, U.; Technoteam GmbH, Ilmenau, GERMANY
Schmidt, F.; Technoteam GmbH, Ilmenau, GERMANY
Hartmann, Jürgen; 7.3, Detektorradiometrie und Strahlungsthermometrie, PTB-Berlin
Quelle/Jahr Metrologia: 46 (2009), 4, S260 - S265
ISSN 0026-1394 (PRINT) ; 1681-7575 (ONLINE)
DOI
Konferenzangaben NEWRAD 2008, 10th International Conference on New Developments and Applications in Optical Radiometry, Daejeon, 13-16, October, 2008, Korea
Zusammenfassung A radiance camera was used to investigate the radiation field emitted by high-temperature black-bodies and fixed-point cavities up to temperatures of 3000 K. In a first steep the cameras applicability to measure the spectral radiance at such high-temperatures was invstigated. In a second step the radiation characteristics of several sources were studied using the camera system, in particular large area fixed-point blackbodies of Cu, Pt-C and ZrC-C. Especially for the ZrC-C fixed-points the radiation field at the cavity opening was found to be non-uniform. This observation explains systematic differences in the plateau shape of large aperture eutectic-fixed-point cells for radiometers with different field-of-view. Using the two dimensional radiance distribution measured with the camera system the deviation of the temperatures measured with interference filter radiometers and radiation thermometers was studied.

Zitierung

Anhalt, K., Lindner, D., Krüger, U., Schmidt, F., & Hartmann, J. (2009). Camera based investigation of high-temperature fixed-points for radiometric application. Metrologia, 46(4), S260–S265. https://doi.org/10.1088/0026-1394/46/4/s24

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag