Zugriffsnummer 22293
Dokumenttyp Konferenzartikel in Zeitschrift
Sprache Englisch
Titel Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities
Autor(in); Institution
Lindborg, L.; Karolinska Institutet, Department of Medical Radiation Physics, Stockholm, SWEDEN
Bolognese-Milsztajn, T.; Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-Roses, FRANCE
Boschung, Markus; Paul Scherrer Institut, Villigen, SWITZERLAND
Coeck, M.; Studiecentrum voor Kernenergie - Centre d'etude de l'energie nucleaire, Mol, BELGIUM
Curzio, G.; Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Pisa, ITALY
d'Errico, Francesco; Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Pisa, ITALY
Fiechtner, Annette; Paul Scherrer Institut, Villigen, SWITZERLAND
Hallfarth, D.; RWE Power AG, Kernkraftwerke Lippe-Ems, Lingen/Ems, GERMANY
Lievens, B.; Belgoprocess n.v., Dessel, BELGIUM
Lillhök, J.-E.; Banverket, Expertstöd, Borlänge, SWEDEN
Lövefors-Daun, A.; Ringhals AB, Väröbacka, SWEDEN
Lacoste, Veronique; Institut de Radioprotection et de Surete Nucleaire, Fontenay-aux-Roses, FRANCE
Luszik-Bhadra, Marlies; 6.5, Neutronenstrahlung, PTB-Braunschweig
Reginatto, Marcel; 6.5, Neutronenstrahlung, PTB-Braunschweig
Schuhmacher, Helmut; 6.5, Neutronenstrahlung, PTB-Braunschweig
Tanner, R.; Radiation Protection Division, Health Protection Agency, Didcot, UK
Vanhavere, F.; Studiecentrum voor Kernenergie - Centre d'etude de l'energie nucleaire, Mol, BELGIUM
Quelle/Jahr Characterization of workplaces for the assessment of doses to individuals : proceedings from the EURADOS scientific symposium. Radiation Protection Dosimetry: 124 (2007), 3, 213 - 218
ISSN 0144-8420
ISBN 978-0-19-954380-9
DOI
Verlag Oxford: Oxford University Press
Konferenzangaben Characterization of workplaces for the assessment of the doses to individuals (AM2007), Madrid, 23, January, 2007, Spain
Zusammenfassung Ratios of Hp(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for Hp(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5 - 1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.

Zitierung

Lindborg, L., Bolognese-Milsztajn, T., Boschung, M., Coeck, M., Curzio, G., d'Errico, F., Fiechtner, A., Hallfarth, D., Lievens, B., Lillhök, J.-E., Lövefors-Daun, A., Lacoste, V., Luszik-Bhadra, M., Reginatto, M., Schuhmacher, H., Tanner, R., & Vanhavere, F. (2007). Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities. Radiation Protection Dosimetry, 124(3), 213–218. https://doi.org/10.1093/rpd/ncm394

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag