Zugriffsnummer 20751
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Summary of the neutron dosemeter results of the EVIDOS project
Autor(in); Institution
Vanhavere, F.; Studiecentrum Kernenergie-Centre d'étude de l'énergie nucléaire, Mol, BELGIUM
Luszik-Bhadra, Marlies; 6.5, Neutronenstrahlung, PTB-Braunschweig
Bartlett, D.; Health Protection Agency, Chilton, Didcot, UK
Bolognese-Milsztajn, T.; Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, FRANCE
Boschung, M.; Paul Scherrer Institut, Villigen, SWITZERLAND
Coeck, M.; Studiecentrum Kernenergie-Centre d'étude de l'énergie nucléaire, Mol, BELGIUM
d'Errico, F.; Dipartimento di Ingegneria Meccanica, Pisa, ITALY
Fiechtner, A.; Paul Scherrer Institut, Villigen, SWITZERLAND
Kyllönen, J.-E.; Swedish Radiation Protection Authority, Stockholm, SWEDEN
Lacoste, V.; Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, FRANCE
Lindborg, L.; Swedish Radiation Protection Authority, Stockholm, SWEDEN
Reginatto, Marcel; 6.5, Neutronenstrahlung, PTB-Braunschweig
Schuhmacher, Helmut; 6.5, Neutronenstrahlung, PTB-Braunschweig
Tanner, R.; Health Protection Agency, Chilton, Didcot, UK
Quelle/Jahr Annalen van de Belgische Vereniging voor Stralingsbescherming = Annales de l'Association belge de Radioprotection: 32 (2007), 1, 65 - 76
ISSN 0250-5010
Verlag Bruxelles:
Zusammenfassung EVIDOS ("Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields") is an European Union (EU) sponsored project that aimed at a signicificant improvement of radiation protection dosimetry in mixed neutron/photon fields. The performance of personal dosemeters and survey instruments was tested in selected workplace fields. Reference values for the dose equivalent quantities, H*(10) and Hp(10) and the effective dose E, are determined using different spectrometers that provide the energy distribution of the neutron fluence. Also newly developed devices are used that determine the energy and directional distribution of the neutron fluence. Under-and over-readings by more than a factor of two for the same dosemeter in different workplace fields indicate that in most cases the use of field-specific correction factors is required. In this paper we will give a short overview of the methods used for the determination of the reference values, and focus on the results of the personal and ambient dosemeters in the diffent fields.

Zitierung

Vanhavere, F., Luszik-Bhadra, M., Bartlett, D., Bolognese-Milsztajn, T., Boschung, M., Coeck, M., d'Errico, F., Fiechtner, A., Kyllönen, J.-E., Lacoste, V., Lindborg, L., Reginatto, M., Schuhmacher, H., & Tanner, R. (2007). Summary of the neutron dosemeter results of the EVIDOS project. Annalen van de Belgische Vereniging voor Stralingsbescherming = Annales de l'Association belge de Radioprotection, 32(1), 65–76.

Exportieren