Zugriffsnummer 20580
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel An approach to validation of rigorous modeling in optical CD microscopy by comparison of measurement results with independent methods
Autor(in); Institution
Bodermann, Bernd; 4.2, Bild- und Wellenoptik, PTB-Braunschweig
Bosse, Harald; 5.2, Längen- und Winkelteilungen, PTB-Braunschweig
Quelle/Jahr Modeling aspects in optical metrology : [papers from the SPIE Conference on Optical Metrology, held as part of the 18th International Congress on Photonics in Europe]:(2007), 66170Y-1 - 66170Y-10
Schriftenreihe Proceedings of SPIE: 6617
Herausgeber(in)
Bosse, Harald; 5.2, Längen- und Winkelteilungen, PTB-Braunschweig
Bodermann, Bernd; 4.2, Bild- und Wellenoptik, PTB-Braunschweig
ISSN 0277-786X
ISBN 978-0-8194-6759-1
DOI
Verlag Bellingham, Wash.: SPIE
Konferenzangaben Modeling Aspects in Optical Metrology, Munich, 18-19, June, 2007, Germany
Freie Schlagworte CD metrology ; rigorous image modeling ; cross calibration ; photomask metrology ; validation
Zusammenfassung Optical measurement methods like high resolution microscopy and scatterometry are widely used in photomask and semiconductor metrology. One of the most important measurement tasks is the characterization of line features for CD or linewidth or more general 3D line shape characteristics. For proper simulation of microscopic imaging rigorous diffraction models were applied on isolated and dense as well as clear and opaque photomask line features. The features were also different with respect to edge angle and edge shape as well as optical properties of photomask absorber structures. We report on the results on special test masks with intended larger edge angle variations as well as on high quality photomask line features on CD standards which are used for the 65 nm semiconductor technology node. In order to be able to compare and validate the uncertainty calculations of these results, systematic comparisons with other independently traceable measurement methods on the same features have been performed. For this cross-calibration analysis low voltage SEM as well as additional AFM measurements were used.

Zitierung

Bodermann, B. & Bosse, H. (2007). An approach to validation of rigorous modeling in optical CD microscopy by comparison of measurement results with independent methods. Modeling Aspects in Optical Metrology, Munich, 18-19, June, 2007, Germany. https://doi.org/10.1117/12.728896