Zugriffsnummer 20173
Dokumenttyp Konferenzartikel in Zeitschrift
Sprache Englisch
Titel Direction distributions of neutrons and reference values of the personal dose equivalent in workplace fields
Autor(in); Institution
Luszik-Bhadra, Marlies; 6.5, Neutronenstrahlung, PTB-Braunschweig
Bolognese-Milsztajn, T.; Institut de Radioprotection et de Sureté Nucléaire, Fontenay-aux-Roses, FRANCE
Boschung, M.; Paul Scherrer Institut (PSI), Villigen, SWITZERLAND
Coeck, M.; Studiecentrum voor Kernenergie, Mol, BELGIUM
Curzio, G.; Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Pisa, ITALY
d'Errico, F.; Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Pisa, ITALY
Fiechtner, A.; Paul Scherrer Institut (PSI), Villigen, SWITZERLAND
Lacoste, V.; Institut de Radioprotection et de Sureté Nucléaire, Fontenay-aux-Roses, FRANCE
Lindborg, L.; Swedish Radiation Protection Authority, Stockholm, SWEDEN
Reginatto, Marcel; 6.5, Neutronenstrahlung, PTB-Braunschweig
Schuhmacher, Helmut; 6.5, Neutronenstrahlung, PTB-Braunschweig
Tanner, R.; Health Protection Agency, Radiation Protection Division, Chilton, UK
Vanhavere, F.; Studiecentrum voor Kernenergie, Mol, BELGIUM
Quelle/Jahr European Workshop on Individual Monitoring of Ionising Radiation (IM2005). Radiation Protection Dosimetry: 125 (2007), 1/4, 364 - 368
ISSN 0144-8420
ISBN 978-0-19-923170-6
DOI
Verlag Oxford: Oxford University Press
Konferenzangaben European Workshop on Individual Monitoring of Ionising Radiation - IM 2005, Vienna, 11-15, April, 2005, Austria
Freie Schlagworte Neutron spectrometry ; Direction distribution ; Personal dose equivalent ; Unfolding
Zusammenfassung Within the EC project EVIDOS, double-differential (energy and direction) fluence spectra were determined by means of novel direction spectrometers. By folding the spectra with fluence-to-dose equivalent conversion coefficients, contributions to H*(10) for 14 directions, and values of the personal dose equivalent Hp(10) and the effective dose E for 6 directions of a person's orientation in the field were determined. The results of the measurements and calculations obtained within the EVIDOS project in workplace fields in nuclear installations in Europe, i.e., at Krümmel (boiling water reactor and transport cask), at Mol (Venus research reactor and fuel facility Belgonucleaire) and at Ringhals (pressurised reactor and transport cask) are presented.

Zitierung

Luszik-Bhadra, M., Bolognese-Milsztajn, T., Boschung, M., Coeck, M., Curzio, G., d'Errico, F., Fiechtner, A., Lacoste, V., Lindborg, L., Reginatto, M., Schuhmacher, H., Tanner, R., & Vanhavere, F. (2007). Direction distributions of neutrons and reference values of the personal dose equivalent in workplace fields. Radiation Protection Dosimetry, 125(1/4), 364–368. https://doi.org/10.1093/rpd/ncm189