Titel Final report on the key comparison EUROMET.AUV.V-K1
Autor(in); Institution
Martens, Hans-Jürgen von; 1.3, Kinematik, PTB-Braunschweig
Elster, Clemens; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Link, Alfred; 8.4, Mathematische Modellierung und Datenanalyse, PTB-Berlin
Täubner, Angelika; 1.3, Kinematik, PTB-Braunschweig
Bruns, Thomas; 1.3, Kinematik, PTB-Braunschweig
Quelle/Jahr Metrologia: 43 (2006), Tech. Suppl., 129 S.
Artikelnummer 09002
Availability [online only]
ISSN 0026-1394 (PRINT) ; 1681-7575 (ONLINE)
DOI
URL
Verlag Bristol [u.a.]: IOP [u.a.]
Freie Schlagworte key comparison ; EUROMET ; CCAUV ; acoustics, ultrasound and vibration
Zusammenfassung The first key comparison (KC) in the Regional Metrology Organization (RMO) EUROMET in the area of “vibration” (EUROMET.AUV.V-K1, Project Ref.-No. 579) was carried out from July 2003 to March 2005, piloted by the PTB. The objective was to link 11 European countries, which had not participated in the CIPM KC, to the key comparison reference values (KCRVs) established in the CIPM KC CCAUV.V-K1. The linking of the RMO KC to the CIPM KC was based on the "weighted mean method" using the results of three laboratories that had participated in both KCs. To measure the charge sensitivity of two transfer standards (accelerometers) at six specified frequencies in the range from 40 Hz to 5 kHz, ten laboratories used laser interferometry (ISO 16063-11) and four laboratories used comparison with a reference transducer (ISO 16063-21) traceable to PTB EUROMET project ref. No. 198 providing traceability). The degrees of equivalence were computed for all calibration results of the RMO laboratories regarding (i) the KCRV, (ii) the other RMO laboratories’ results, and (iii) the results of the 12 laboratories which had participated in the CIPM KC. In all cases the deviation Di relative to the KCRV is smaller than the relative expanded uncertainty Ui (k = 2) of this difference, Di < Ui. The deviations Dij between the laboratories are in nearly 99 % of all cases smaller than the relative expanded uncertainty Uij (k = 2) of these differences. None of the calibration results (40 Hz to 5 kHz) exceeds a relative deviation of 1 % from the KCRV, and only a few results deviate by more than 0.5 % from the KCRV. Orig.-Titel des Reports: Final report of key comparison EUROMET.AUV.V-K1

Zitierung

Martens, H.-J. V., Elster, C., Link, A., Täubner, A., & Bruns, T. (2006). Final report on the key comparison EUROMET.AUV.V-K1. Metrologia, 43(Tech. Suppl.), 129 S. https://doi.org/10.1088/0026-1394/43/1a/09002

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag