| Zugriffsnummer | 19144 |
| Dokumenttyp | Konferenzartikel in Zeitschrift |
| Peer Review | unbekannt |
| Sprache | Englisch |
| Titel | Performance of the electronic personal dosemeter for neutron 'saphydose-N' at different workplaces of nuclear facilities |
| Autor(in); Institution |
Lahaye, T.; Institut for Radiological Protection and Nuclear Safety, Fontenay-aux-Roses, FRANCE
Chau, Q.; Institut for Radiological Protection and Nuclear Safety, Fontenay-aux-Roses, FRANCE
Ménard, S.; Institut for Radiological Protection and Nuclear Safety, Fontenay-aux-Roses, FRANCE
Lacoste, V.; Institut for Radiological Protection and Nuclear Safety, Fontenay-aux-Roses, FRANCE
Muller, H.; Institut for Radiological Protection and Nuclear Safety, Fontenay-aux-Roses, FRANCE
Luszik-Bhadra, Marlies; 6.5, Neutronenstrahlung, PTB-Braunschweig
Reginatto, Marcel; 6.5, Neutronenstrahlung, PTB-Braunschweig
Bruguier, P.; Service of Protection against Radiation, Cadarache, St. Paul-lez-Durance, FRANCE
|
| Quelle/Jahr | Solid State Dosimetry : proceedings of the 14. International Conference on Solid State Dosimetry. Radiation Protection Dosimetry: 120 (2006), 1/4, 383 - 386 |
| ISSN | 1742-3406 (ONLINE) ; 0144-8420 (PRINT) |
| DOI | |
| Verlag | Oxford: Oxford Univ. Press |
| Konferenzangaben | 14th International Conference on Solid State Dosimetry, New Haven, Yale University, 27, June - 02, July, 2004, USA |
| Zusammenfassung | This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS (‘Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields’). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources (241AmBe;252Cf; 252Cf(D2O)and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucleaire, a fuel processing factory. |
Zitierung
Lahaye, T., Chau, Q., Ménard, S., Lacoste, V., Muller, H., Luszik-Bhadra, M., Reginatto, M., & Bruguier, P. (2006). Performance of the electronic personal dosemeter for neutron 'saphydose-N' at different workplaces of nuclear facilities. Radiation Protection Dosimetry, 120(1/4), 383–386. https://doi.org/10.1093/rpd/nci635