Zugriffsnummer 18297
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Determination of the unit of the inductance with the Maxwell-Wien-bridge in PTB
Autor(in); Institution
Hanke, Rüdiger; 2.1, Gleichstrom und Niederfrequenz, PTB-Braunschweig
Skubis, Tadeusz; Silesian Technical University of Technology, Gliwice, POLAND
Kölling, Axel; 2.1, Gleichstrom und Niederfrequenz, PTB-Braunschweig
Quelle/Jahr [Regional Metrology Conference - RMC 2005]:(2005)
Availability [CD-ROM] ; file name: Nairobi_Hanke.doc
Verlag s.l.:
Konferenzangaben Regional Metrology Conference 2005, Nairobi, 19-20, September, 2005, Kenya
Zusammenfassung For the determination of the unit Henry of the inductance at PTB a Maxwell-Wien bridge has been developed. The advantage of this type of bridge is that the first order equation is independent of frequency and therefore works well in a frequency range from 50 Hz up to 1MHz. The bridge includes a Wagner device to eliminate stray and cable capacitances. It is necessary to consider the frequency dependence of the used primary standards to decrease the desired uncertainties of the determinated unit Henry.

Zitierung

Hanke, R., Skubis, T., & Kölling, A. (2005). Determination of the unit of the inductance with the Maxwell-Wien-bridge in PTB. Regional Metrology Conference 2005, Nairobi, 19-20, September, 2005, Kenya.