Zugriffsnummer 16807
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel The European project TRIRAT: arrangements for and results of the comparison of local temperature scales with transfer infrared thermometers between 150 °C and 962 °C
Autor(in); Institution
Battuello, M.; Istituto di Metrologia Gustavo Colonnetti (IMGC), Torino, ITALY
Girard, F.; Istituto di Metrologia Gustavo Colonnetti (IMGC), Torino, ITALY
Ricolfi, T.; Istituto di Metrologia Gustavo Colonnetti (IMGC), Torino, ITALY
Sadli, M.; Bureau National de Metrologie, Institut National de Metrologie (BNM-INM), Paris, FRANCE
Ridoux, P.; Bureau National de Metrologie (BNM-LNE), Paris, FRANCE
Enouf, O.; Bureau National de Metrologie (BNM-LNE), Paris, FRANCE
Perez, J.; CEM, Madrid, SPAIN
Chimenti, V.; CEM, Madrid, SPAIN
Wekström, T.; CMA, Helsinki, FINLAND
Struss, O.; Heitronics, Wiesbaden, GERMANY
Filipe, E.; IPQ, Caparica, PORTUGAL
Machado, N.; IPQ, Caparica, PORTUGAL
Ham, E. van der; Nederlands Meetinstituut, Van Swinden Laboratorium (NMi-VSL), Delft, THE NETHERLANDS
Machin, G.; National Physical Laboratory (NPL), Teddington, UK
Mc Evoy, H.; National Physical Laboratory (NPL), Teddington, UK
Gutschwager, Berndt; 7.21, Temperaturstrahlung, PTB-Berlin
Fischer, Joachim; 7.3, Temperatur und Wärme, PTB-Berlin
Schmidt, V.; Raytek GmbH, Berlin, GERMANY
Clausen, S.; RISOE, Roskilde, DENMARK
Ivarsson, J.; SP, Boras, SWEDEN
Ugur, S.; Ulusal Metroloji Enstitüsü (UME), Gezbe-Kocaeli, TURKEY
Diril, A.; Ulusal Metroloji Enstitüsü (UME), Gezbe-Kocaeli, TURKEY
Quelle/Jahr Temperature - its measurement and control in science and industry: 2 (2003), 903 - 908
Schriftenreihe AIP Conference Proceedings: 684
ISBN 0-7354-0153-5
DOI
Verlag Melville, NY: American Inst. of Physics
Konferenzangaben TEMPERATURE 2002, The 8th Symposium: Its measurement and control in science and industry, Chicago, Illinois, 21-24, October, 2002, USA
Klassifikationscode PACS: 07.20.Dt
Zusammenfassung In the course of the EC-funded project TRIRAT ("TRaceability in Infrared Radiation Thermometry") an international comparison of local radiation temperature scales took place among fourteen laboratories in the temperature range from 150 °C to 962 °C. This paper describes the equipment and the transfer standards used for the comparison. The results and the procedures adopted for deriving a "comparison reference value" (CRV) and the degree of equivalence of each laboratory with respect to the CRV are then discussed. The different arrangements adopted for the calibration of the thermometers and additional experimental investigations allowed an analysis on the effect of some influencing parameters, e.g., the size of source effect (SSE), to be performed and indications on the most convenient experimental arrangements to be derived.

Zitierung

Battuello, M., Girard, F., Ricolfi, T., Sadli, M., Ridoux, P., Enouf, O., Perez, J., Chimenti, V., Wekström, T., Struss, O., Filipe, E., Machado, N., Ham, E. V. D., Machin, G., Mc Evoy, H., Gutschwager, B., Fischer, J., Schmidt, V., Clausen, S., Ivarsson, J., Ugur, S., & Diril, A. (2003). The European project TRIRAT: arrangements for and results of the comparison of local temperature scales with transfer infrared thermometers between 150 °C and 962 °C. TEMPERATURE 2002, The 8th Symposium: Its measurement and control in science and industry, Chicago, Illinois, 21-24, October, 2002, USA. https://doi.org/10.1063/1.1627243