Zugriffsnummer 14918
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Determination of the temperatures of metal-carbon eutectic fixed-points by different detectors from VNIIOF, NPL, and PTB
Autor(in); Institution
Khlevnoy, B.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Khromchenko, V.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Samoylov, M.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Sapritsky, V.; All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow, RUSSIA
Harrison, N.; National Physical Laboratory (NPL), Teddington, UK
Sperfeld, Peter; 4.11, Radiometrische Einheiten, PTB-Braunschweig
Fischer, Joachim; 7.3, Temperatur und Wärme, PTB-Berlin
Quelle/Jahr TEMPMEKO 2001, 8th International Symposium on Temperature and Thermal Measurements in Industry and Science: Proceedings: 2 (2002), 845 - 850
Herausgeber(in)
Fellmuth, Bernd; 7.32, Tieftemperaturmetrologie, PTB-Berlin
Seidel, Joachim; 7.2, Hochtemperaturphysik und Vakuum, PTB-Berlin
Scholz, Günter; 3.23, Analytische Messtechnik und Feuchte, PTB-Braunschweig
ISBN 3-8007-2676-9
Verlag Berlin [u.a.]: VDE-Verl.
Konferenzangaben 8th International Symposium on Temperature and Thermal Measurements in Industry and Science ; TEMPMEKO, Berlin, 19-21, June, 2001, Germany
Freie Schlagworte temperature scale ; fixpoint ; eutectic ; blackbody ; black body ; ITS-90
Zusammenfassung Melting and freezing temperatures of Ir-C and Re-C eutectic fixed-point blackbody cavities were determined for the first time during a joint experiment using detectors from NPL, PTB and VNIIOFI which were all radiance-mode narrowband interference-filter based detectors calibrated against either national realisations of the Temperature Scale ITS-90 or radiometric detector scales. The average values of the observed melting temperatures for one Ir-C and one Re-C eutectic crucible were 2564.3 K and 2748.5 K, respectively. The corresponding values for the freezing points were 2564.6 K and 2748.2 K, respectively. The standard deviations were not larger than 0.2 K, which is well below the individual calibration uncertainties of the detectors.

Zitierung

Khlevnoy, B., Khromchenko, V., Samoylov, M., Sapritsky, V., Harrison, N., Sperfeld, P., & Fischer, J. (2002). Determination of the temperatures of metal-carbon eutectic fixed-points by different detectors from VNIIOF, NPL, and PTB. 8th International Symposium on Temperature and Thermal Measurements in Industry and Science ; TEMPMEKO, Berlin, 19-21, June, 2001, Germany.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag