Zugriffsnummer 14904
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel The European ACQHE project: Modular system for the calibration of capacitance standards based on the quantum Hall effect [poster]
Autor(in); Institution
Melcher, Jürgen; 2.11, Wechselstromgrößen, PTB-Braunschweig
Schurr, Jürgen; 2.11, Wechselstromgrößen, PTB-Braunschweig
Pierz, Klaus; 2.41, Halbleiterstrukturen, PTB-Braunschweig
Williams, J. M.; National Physical Laboratory (NPL), Teddington, UK
Giblin, S. P.; National Physical Laboratory (NPL), Teddington, UK
Cabiati, F.; Istituto Elettrotecnico Nazionale Galileo Ferraris (IEN), Torino, ITALY
Callegaro, L.; Istituto Elettrotecnico Nazionale Galileo Ferraris (IEN), Torino, ITALY
Marullo, G. C.; Istituto Elettrotecnico Nazionale Galileo Ferraris (IEN), Torino, ITALY
Cassiago, C.; Istituto Elettrotecnico Nazionale Galileo Ferraris (IEN), Torino, ITALY
Jeckelmann, B.; Swiss Federal Office of Metrology and Accreditation (METAS), Bern-Wabern, SWITZERLAND
Jeanneret, B.; Swiss Federal Office of Metrology and Accreditation (METAS), Bern-Wabern, SWITZERLAND
Overney, F.; Swiss Federal Office of Metrology and Accreditation (METAS), Bern-Wabern, SWITZERLAND
Boh.aacute.šek, J.; Czech Technical University, Faculty of Electrical Engineering, Prague, CZECH REPUBLIC
Riha, J.; Czech Technical University, Faculty of Electrical Engineering, Prague, CZECH REPUBLIC
Power, O.; National Metrology Laboratory, Enterprise Ireland, Dublin, IRELAND
Murray, J.; National Metrology Laboratory, Enterprise Ireland, Dublin, IRELAND
Nunes, M.; Instituto Nacional Engenharia e Tecnologia Industrial, Lisboa, PORTUGAL
Lobo, M.; Instituto Nacional Engenharia e Tecnologia Industrial, Lisboa, PORTUGAL
Godinho, I.; Instituto Nacional Engenharia e Tecnologia Industrial, Lisboa, PORTUGAL
Quelle/Jahr Conference digest : 2002 Conference on Precision Electromagnetic Measurements:(2002), 250 - 251
ISBN 0-7803-7242-5
Verlag Piscataway, NJ: IEEE
Konferenzangaben Conference on Precision Electromagnetic Measurements ; CPEM 2002, Ottawa, 16-21, June, 2002, Canada
Zusammenfassung Starting in 1998 a project funded by the European Commission has been carried out in a co-operation of seven partners. The aim of this project was to establish a measurement system which allows the calibration of standard capacitors in terms of RK-90. The whole system comprises suitable quantum Hall samples, an automated bridge system and auxiliary devices to calibrate and characterize the whole set-up. The uncertainty for the calibration of a 10-pF capacitor is about 1 part in 107.

Zitierung

Melcher, J., Schurr, J., Pierz, K., Williams, J. M., Giblin, S. P., Cabiati, F., Callegaro, L., Marullo, G. C., Cassiago, C., Jeckelmann, B., Jeanneret, B., Overney, F., Boh.aacute.šek, J., Riha, J., Power, O., Murray, J., Nunes, M., Lobo, M., & Godinho, I. (2002). The European ACQHE project: Modular system for the calibration of capacitance standards based on the quantum Hall effect [poster]. Conference on Precision Electromagnetic Measurements ; CPEM 2002, Ottawa, 16-21, June, 2002, Canada.

Exportieren

PTB-Publica Menü

Sprache wechseln: uk flag