| Zugriffsnummer | 14072 |
| Dokumenttyp | Konferenzartikel in Zeitschrift |
| Sprache | Englisch |
| Titel | International comparison of a pulse calibrator used in high voltage impulse calibration |
| Autor(in); Institution |
Li, Yi; National Measurement Laboratory, CSIRO, Lindfield, AUSTRALIA
Rungis, Juris; National Measurement Laboratory, CSIRO, Lindfield, AUSTRALIA
McComb, Terry; Electrical Power Measurements for National Measurement Standards, Ottawa, CANADA
Lucas, Wolfgang; 2.31, Messwandler und Hochspannungstechnik, PTB-Braunschweig
|
| Quelle/Jahr | IEEE Transactions on Instrumentation and Measurement: 50 (2001), 2, 430 - 435 |
| ISSN | 0018-9456 |
| Verlag | New York, NY: IEEE |
| Konferenzangaben | 22nd Conference on Precision Electromagnetic Measurements ; CPEM 2000, Sydney, 14-19, May, 2000, Australia |
| Freie Schlagworte | Impulse measurement ; Measurement uncertainty ; Pulse calibrator |
| Zusammenfassung | Measurement on a pulse generatorm, which was made and characterized by the National Measurement Laboratory (NML), Australia, have been made at the National Research Council (NRC) in Canada and the Physikalisch-Technische Bundesanstalt (PTB) in Germany. Most of the measured peak values (Vp) among the laboratories agree to ± 0.5%, the front times (T1) to ± 2.0%, and the times to half values (T2) to ± 1.0%. The differences between calculated calibrator outputs and measured averages were found to be 0.13%, 0.63%, and 0.32% for Vp, T1, and T2, respectively. Contributions of impulse analysis software to the measured errors are also discussed. |