Zugriffsnummer 13610
Dokumenttyp Zeitschriftenartikel
Sprache Englisch
Titel Dependence of the outgassing rate of a "vacuum fired" 316LN stainless steel chamber on bake-out temperature
Autor(in); Institution
Jousten, Karl; 7.23, Vakuummetrologie, PTB-Berlin
Quelle/Jahr Vacuum: 49 (1998), 4, 359 - 360
ISSN 0042-207X
DOI
Verlag Amsterdam [u.a.]: Elsevier
Zusammenfassung It was found that the outgassing rate of a vacuum fired 316 LN stainless steel chamber increased with bake-out temperature in the range of 100 °C to 180 °C.

Zitierung

Jousten, K. (1998). Dependence of the outgassing rate of a "vacuum fired" 316LN stainless steel chamber on bake-out temperature. Vacuum, 49(4), 359–360. https://doi.org/10.1016/s0042-207x(98)00002-5