| Zugriffsnummer | 12705 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | The influence of misalignment on torque transducers |
| Autor(in); Institution |
Brüge, Andreas; 1.13, Drehmoment, PTB-Braunschweig
Peschel, Diedert; 1.13, Drehmoment, PTB-Braunschweig
Röske, Dirk; 1.13, Drehmoment, PTB-Braunschweig
|
| Quelle/Jahr | Proceedings, XVI IMEKO World Congress, IMEKO 2000: 3 (2000), 13 - 17 |
| Herausgeber(in) |
Osanna, P. H.; Austrian Society for Measurement and Automation
|
| ISBN | 3-901888-05-5 |
| Verlag | Wien: Eigenverlag ÖGMA |
| Konferenzangaben | XVI IMEKO World Congress ; IMEKO 2000, Vienna, 25-28, September, 2000, Austria |
| Freie Schlagworte | torque ; calibration ; misalignment ; flexible coupling |
| Zusammenfassung | Misalignment during the mounting of torque transducers in calibration devices can cause parasitic bending inside the transducers. Flexible couplings allow the contribution of misalignment to the measurement uncertainty to be reduced to a negligible amount. The proceedings are also available on CD-ROM. |