| Zugriffsnummer | 12441 |
| Dokumenttyp | Konferenzartikel |
| Sprache | Englisch |
| Titel | New ac-dc transfer step-up calibration and uncertainty calculation in PTB and INTI |
| Autor(in); Institution |
Klonz, Manfred; 2.32, Wechsel-Gleich-Transfer, PTB-Braunschweig
Laiz, H.; Institutio Nacional de Tecnologia Industrial (INTI), San Martin, ARGENTINA
|
| Quelle/Jahr | 2000 Conference on Precision Electromagnetic Measurements digest:(2000), 490 - 491 |
| Herausgeber(in) |
Hunter, John; National Management Laboratory, CSIRO, AUSTRALIA
|
| ISBN | 0-7803-5744-2 |
| Verlag | Piscataway, NJ: IEEE |
| Konferenzangaben | Conference on precision electromagnetic measurements (CPEM 2000), Sydney, 14-19, May, 2000, Australia |
| Freie Schlagworte | AC-DC voltage ; Planar Multijunction Thermal Converters ; High sensitivity |
| Zusammenfassung | In PTB and INTI new ac-dc voltage transfer standards are built for the voltage range of 0.1 V to 1000 V and the frequency range of 10 Hz to 1 MHz. PMJTC (Planar Multijunction Thermal Converters) and coaxial voltage dropping resistors are used in the step-up procedure for the different voltage levels. For voltages > 100 V new planar resistors are used to guarantee the voltage independence of the ac-dc transfer difference. The high sensitivity of the PMJTC allows big steps in the step-up calibration and many steps inbetween which leads to an overdetermined system to check the validity of the assumptions used in the step-up. The uncertainty budget for the different voltage levels is calculated. |