Zugriffsnummer 12434
Dokumenttyp Konferenzartikel
Sprache Englisch
Titel Fundamental determination of the loss factor of 1 μF capacitors at 1 kHz
Autor(in); Institution
Ramm, Günther; 2.102, Messung nichtelektrischer Grössen, PTB-Braunschweig
Moser, Harald; 2.102, Messung nichtelektrischer Grössen, PTB-Braunschweig
Quelle/Jahr 2000 Conference on Precision Electromagnetic Measurements digest:(2000), 133 - 134
Herausgeber(in)
Hunter, John; National Management Laboratory, CSIRO, AUSTRALIA
ISBN 0-7803-5744-2
Verlag Piscataway, NJ: IEEE
Konferenzangaben Conference on precision electromagnetic measurements (CPEM 2000), Sydney, 14-19, May, 2000, Australia
Zusammenfassung This paper present a new measuring method which allows the loss factor of 1 μF capacitors to be derived from the calculable time constant of a 200 Ω AC resistor of bifilar structure. The method combines elements of the traditional bridge technique (Thomson balancing and Wagner earthing) with the digital synthesis of signals and their sampling using the discrete Fourier transform (DFT). The method allows the loss factor to be determined with an estimated standard uncertainty of measurement (k = 1) of 2×10-6

Zitierung

Ramm, G. & Moser, H. (2000). Fundamental determination of the loss factor of 1 μF capacitors at 1 kHz. Conference on precision electromagnetic measurements (CPEM 2000), Sydney, 14-19, May, 2000, Australia.